1994CytometryOpen access

Light scatter based lymphocyte gate–helpful tool or source of error?

Elisabeth Krömer, Friedrich Grossmüller

Open full text 9 citations

Abstract

During flow cytometric analysis of 29 samples of human peripheral blood mononuclear cells, we observed that a light scatter-based lymphocyte gate would fail to cover all TCR (CD3)-expressing cells. A mean of 7.9 +/- 5.3% of all CD3+ cells was found outside the gate. In addition, this shifted cell subset showed an altered CD4/CD8 ratio (8.1 +/- 5.0% of all CD4+ and 13.7 +/- 5.8% of all CD8+ cells). The use of standard light scatter-based lymphocyte gates in acquisition and/or analysis of flow cytometry (FCM) data may thus lead to erroneous results, particularly if T cells are to be studied.

Open-access reader

About this research paper

What this paper is about

During flow cytometric analysis of 29 samples of human peripheral blood mononuclear cells, we observed that a light scatter-based lymphocyte gate would fail to cover all TCR (CD3)-expressing cells. A mean of 7.9 +/- 5.3% of all CD3+ cells was found outside the gate. In addition, this shifted cell subset showed an altered CD4/CD8 ratio (8.1 +/- 5.0% of all CD4+ and 13.7 +/- 5.8% of all CD8+ cells). The use of standard light scatter-based lymphocyte gates in acquisition and/or analysis of flow cytometry (FCM) data may thus lead to erroneous results, particularly if T cells are to be studied.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

During flow cytometric analysis of 29 samples of human peripheral blood mononuclear cells, we observed that a light scatter-based lymphocyte gate would fail to cover all TCR (CD3)-expressing cells. A mean of 7.9 +/- 5.3% of all CD3+ cells was found outside the gate. In addition, this shifted cell subset showed an altered CD4/CD8 ratio (8.1 +/- 5.0% of all CD4+ and 13.7 +/- 5.8% of all CD8+ cells). The use of standard light scatter-based lymphocyte gates in acquisition and/or analysis of flow cytometry (FCM) data may thus lead to erroneous results, particularly if T cells are to be studied.

Key concepts: CD3, Flow cytometry, CD8, Cytometry, Lymphocyte, Peripheral blood mononuclear cell, T lymphocyte, Lymphocyte subsets

Related papers

Back to paper searchBrowse research topicsOriginal source
Light scatter based lymphocyte gate–helpful tool or source of error? — Research Paper | ScholarLens