1983•Clinical Chemistry and Laboratory Medicine (CCLM)Open access

Latex Immunoassay of Urinary Albumin

A M Bernard, Robert Lauwerys

Open full text 19 citations

Abstract

A new non isotopic immunoassay based on latex particle agglutination has been developed for the determination of albumin in urine. The assay consists in incubating the urine sample for 30 min at 37 degrees C with latex particles coated with a specific antibody, followed by quantification of the resulting agglutination by particle counting or turbidimetry. The stability of antibody-coated particles during incubation is achieved by diluting them just before the assay in a buffer containing bovine serum albumin. The pH of this buffer, the antibody loading and the concentration of latex particles in the incubation mixture were optimized to obtain the maximal specific and minimal nonspecific agglutination. The albumin standard curve ranges from 25 to 800 micrograms/l. Reproducibility tests performed within and between run gave CV's ranging from 8.2 to 11.6%. The recovery of albumin added to 10 urines averaged 95.5%. A correlation coefficient of 0.96 was obtained between latex immunoassay and nephelometry for the determination of albumin in 51 urines.

Open-access reader

About this research paper

What this paper is about

A new non isotopic immunoassay based on latex particle agglutination has been developed for the determination of albumin in urine. The assay consists in incubating the urine sample for 30 min at 37 degrees C with latex particles coated with a specific antibody, followed by quantification of the resulting agglutination by particle counting or turbidimetry. The stability of antibody-coated particles during incubation is achieved by diluting them just before the assay in a buffer containing bovine serum albumin. The pH of this buffer, the antibody loading and the concentration of latex particles in the incubation mixture were optimized to obtain the maximal specific and minimal nonspecific agglutination. The albumin standard curve ranges from 25 to 800 micrograms/l. Reproducibility tests performed within and between run gave CV's ranging from 8.2 to 11.6%. The recovery of albumin added to 10 urines averaged 95.5%. A correlation coefficient of 0.96 was obtained between latex immunoassay and nephelometry for the determination of albumin in 51 urines.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new non isotopic immunoassay based on latex particle agglutination has been developed for the determination of albumin in urine. The assay consists in incubating the urine sample for 30 min at 37 degrees C with latex particles coated with a specific antibody, followed by quantification of the resulting agglutination by particle counting or turbidimetry. The stability of antibody-coated particles during incubation is achieved by diluting them just before the assay in a buffer containing bovine serum albumin. The pH of this buffer, the antibody loading and the concentration of latex particles in the incubation mixture were optimized to obtain the maximal specific and minimal nonspecific agglutination. The albumin standard curve ranges from 25 to 800 micrograms/l. Reproducibility tests performed within and between run gave CV's ranging from 8.2 to 11.6%. The recovery of albumin added to 10 urines averaged 95.5%. A correlation coefficient of 0.96 was obtained between latex immunoassay and nephelometry for the determination of albumin in 51 urines.

Key concepts: Turbidimetry, Chromatography, Nephelometry, Immunoassay, Bovine serum albumin, Chemistry, Latex fixation test, Albumin

Related papers

Back to paper searchBrowse research topicsOriginal source
Latex Immunoassay of Urinary Albumin — Research Paper | ScholarLens