1982•IEEE Transactions on Nuclear ScienceRequires access

Performance and Applications of Passivated Ion-Implanted Silicon Detectors

J. Kemmer, Paul Burger, Roland Henck, Erik H.M. Heijne

Open publisher page 71 citations

Abstract

Planar process has been applied to the fabrication of nuclear radiation detectors. Combining techniques of oxide passivation, photoengraving and ion implantation any desired detector shape can be made with small tolerances in geometrical and electrical properties. Extremely low reverse currents are obtained (less than 1 nA cm-2/100 μm at room temperature) and therefore excellent energy resolutions : 10.6 keV for 5.486 MeV alphas, 1.55 keV for 122 keV gamma-rays with 25 mm2 area detectors, 300 μm thick. The detectors are capable to be backed at 200° C under vacuum. Due to the fact that arrangements of many detectors on one wafer can be made, new possibilities open up, especially for particle localization in high energy physics. Planar versions of 200, 50 and 20 μm pitch parallel microstrip detectors have been realized. Results obtained using a beam of 10 GeV/c pions are presented. Close mounting of several detectors allows the construction of telescopes used as live target in high energy physics experiments.

About this research paper

What this paper is about

Planar process has been applied to the fabrication of nuclear radiation detectors. Combining techniques of oxide passivation, photoengraving and ion implantation any desired detector shape can be made with small tolerances in geometrical and electrical properties. Extremely low reverse currents are obtained (less than 1 nA cm-2/100 μm at room temperature) and therefore excellent energy resolutions : 10.6 keV for 5.486 MeV alphas, 1.55 keV for 122 keV gamma-rays with 25 mm2 area detectors, 300 μm thick. The detectors are capable to be backed at 200° C under vacuum. Due to the fact that arrangements of many detectors on one wafer can be made, new possibilities open up, especially for particle localization in high energy physics. Planar versions of 200, 50 and 20 μm pitch parallel microstrip detectors have been realized. Results obtained using a beam of 10 GeV/c pions are presented. Close mounting of several detectors allows the construction of telescopes used as live target in high energy physics experiments.

Why it matters

OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Planar process has been applied to the fabrication of nuclear radiation detectors. Combining techniques of oxide passivation, photoengraving and ion implantation any desired detector shape can be made with small tolerances in geometrical and electrical properties. Extremely low reverse currents are obtained (less than 1 nA cm-2/100 μm at room temperature) and therefore excellent energy resolutions : 10.6 keV for 5.486 MeV alphas, 1.55 keV for 122 keV gamma-rays with 25 mm2 area detectors, 300 μm thick. The detectors are capable to be backed at 200° C under vacuum. Due to the fact that arrangements of many detectors on one wafer can be made, new possibilities open up, especially for particle localization in high energy physics. Planar versions of 200, 50 and 20 μm pitch parallel microstrip detectors have been realized. Results obtained using a beam of 10 GeV/c pions are presented. Close mounting of several detectors allows the construction of telescopes used as live target in high energy physics experiments.

Key concepts: Detector, Wafer, Physics, Fabrication, Planar, Particle detector, Silicon, Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance and Applications of Passivated Ion-Implanted Silicon Detectors — Research Paper | ScholarLens