2006•The Journal of the Acoustical Society of AmericaRequires access

Interpreting passive cavitation detection signals during high-intensity focused ultrasound (HIFU)

Jamie R. T. Collin, Constantin C. Coussios

Open publisher page 0 citations

Abstract

Inertial cavitation is known to be associated with significantly enhanced rates of heating during cancer treatment by high-intensity focused ultrasound (HIFU). However, during prolonged exposure, the cavitation region gradually shifts towards the HIFU transducer, causing shielding of the original focus. It is hoped that controlling the HIFU field to constrain cavitation to the focal region will lead to sustained enhanced focal heating, thus reducing treatment times and improving treatment resolution. Monitoring of cavitation can be achieved during insonation by using a focussed passive cavitation detector (PCD) to listen for broadband noise emissions resulting from microbubble collapse. The ability to effectively control the cavitation field relies on accurate interpretation of the PCD data. During HIFU exposure of a tissue-mimicking material, it was noted that the frequency content of the PCD signal shifted downwards with increasing phantom propagation path length to the PCD, as a result of depth-dependent attenuation. This has significant implications for the effective sensing volume of the PCD. In addition, it was noted that separate analysis of the peak and rms time-domain PCD values provides an incomplete description of inertial cavitation activity, but that combining these two parameters enables a better understanding of bubble cloud dynamics.

About this research paper

What this paper is about

Inertial cavitation is known to be associated with significantly enhanced rates of heating during cancer treatment by high-intensity focused ultrasound (HIFU). However, during prolonged exposure, the cavitation region gradually shifts towards the HIFU transducer, causing shielding of the original focus. It is hoped that controlling the HIFU field to constrain cavitation to the focal region will lead to sustained enhanced focal heating, thus reducing treatment times and improving treatment resolution. Monitoring of cavitation can be achieved during insonation by using a focussed passive cavitation detector (PCD) to listen for broadband noise emissions resulting from microbubble collapse. The ability to effectively control the cavitation field relies on accurate interpretation of the PCD data. During HIFU exposure of a tissue-mimicking material, it was noted that the frequency content of the PCD signal shifted downwards with increasing phantom propagation path length to the PCD, as a result of depth-dependent attenuation. This has significant implications for the effective sensing volume of the PCD. In addition, it was noted that separate analysis of the peak and rms time-domain PCD values provides an incomplete description of inertial cavitation activity, but that combining these two parameters enables a better understanding of bubble cloud dynamics.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Inertial cavitation is known to be associated with significantly enhanced rates of heating during cancer treatment by high-intensity focused ultrasound (HIFU). However, during prolonged exposure, the cavitation region gradually shifts towards the HIFU transducer, causing shielding of the original focus. It is hoped that controlling the HIFU field to constrain cavitation to the focal region will lead to sustained enhanced focal heating, thus reducing treatment times and improving treatment resolution. Monitoring of cavitation can be achieved during insonation by using a focussed passive cavitation detector (PCD) to listen for broadband noise emissions resulting from microbubble collapse. The ability to effectively control the cavitation field relies on accurate interpretation of the PCD data. During HIFU exposure of a tissue-mimicking material, it was noted that the frequency content of the PCD signal shifted downwards with increasing phantom propagation path length to the PCD, as a result of depth-dependent attenuation. This has significant implications for the effective sensing volume of the PCD. In addition, it was noted that separate analysis of the peak and rms time-domain PCD values provides an incomplete description of inertial cavitation activity, but that combining these two parameters enables a better understanding of bubble cloud dynamics.

Key concepts: Cavitation, High-intensity focused ultrasound, Acoustics, Materials science, Transducer, Ultrasound, Attenuation, SIGNAL (programming language)

Related papers

Back to paper searchBrowse research topicsOriginal source
Interpreting passive cavitation detection signals during high-intensity focused ultrasound (HIFU) — Research Paper | ScholarLens