Separation of Cis- and Trans-Cypermethrin by Reversed-Phase High-Performance Liquid Chromatography
Wei Hu, Weihong Xie, Shaohua Chen, Nan Zhang, Y. Zou, Xiaoli Dong, Md. Mamun Or Rashid, Ying Xiao, Mei Hu, Guoyue Zhong
Abstract
Wei Hu, Weihong Xie, Shaohua Chen, Nan Zhang, Y. Zou, Xiaoli Dong, Md. Mamun Or Rashid, Ying Xiao, Mei Hu, Guoyue Zhong
Abstract
As a pyrethroid insecticide, cypermethrin (CP) possesses three chiral centers and thus consists of eight optical isomers. High-performance liquid chromatography (HPLC) methods have been established for the separation and determination of pyrethroid insecticides. In this article, we report a new reversed-phase high-performance liquid chromatography (RP-HPLC) method of separating the diastereomers of CP. Our method was performed on a C18 column with the following specifications: mobile phase, methanol/acetonitrile/water (58:18:24, v/v/v); flow rate, 1.0 mL/min; column temperature, 20°C and UV-detection wavelength, 235 nm. The results showed that the applied procedure was linear based on calibration curves with equation (y = 16.595x + 1.7892) within the CP concentration range of 5-100 mg/L. The limit of detection and limit of quantification of CP were 0.2 and 0.7 mg/L, respectively. CP or β-CP extracted from the microbial degradation system was determined, and the method was proved to be accurate and applicable. Therefore, the proposed RP-HPLC method was simple, inexpensive and can be used to study stability and determine CP residues in pharmaceutical preparations or in the environment.
OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
As a pyrethroid insecticide, cypermethrin (CP) possesses three chiral centers and thus consists of eight optical isomers. High-performance liquid chromatography (HPLC) methods have been established for the separation and determination of pyrethroid insecticides. In this article, we report a new reversed-phase high-performance liquid chromatography (RP-HPLC) method of separating the diastereomers of CP. Our method was performed on a C18 column with the following specifications: mobile phase, methanol/acetonitrile/water (58:18:24, v/v/v); flow rate, 1.0 mL/min; column temperature, 20°C and UV-detection wavelength, 235 nm. The results showed that the applied procedure was linear based on calibration curves with equation (y = 16.595x + 1.7892) within the CP concentration range of 5-100 mg/L. The limit of detection and limit of quantification of CP were 0.2 and 0.7 mg/L, respectively. CP or β-CP extracted from the microbial degradation system was determined, and the method was proved to be accurate and applicable. Therefore, the proposed RP-HPLC method was simple, inexpensive and can be used to study stability and determine CP residues in pharmaceutical preparations or in the environment.
Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Detection limit, Calibration curve, Pyrethroid, Diastereomer, Cypermethrin