1992The AnalystRequires access

Determination of cadmium in biological samples by inductively coupled plasma atomic emission spectrometry after extraction with 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide

J. M. Espinosa Almendro, C. Bosch Ojeda, A. Garcı́a de Torres, José Manuel Cano Pavón

Open publisher page 9 citations

Abstract

An inductively coupled plasma atomic emission spectrometric method for the determination of trace amounts of cadmium after extraction of the metal into isobutyl methyl ketone containing 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide is described. The optimum extraction conditions were evaluated from a critical study of the effects of pH, concentration of extractant, shaking time and ionic strength. The detection limit for cadmium is 0.1 ng ml-1 and the calibration is linear from 0.2 to 140 ng ml-1. The relative standard deviation for ten replicate measurements is 2.9% for 2 ng ml-1 of cadmium. Results from the analysis of some certified biological reference materials are given.

About this research paper

What this paper is about

An inductively coupled plasma atomic emission spectrometric method for the determination of trace amounts of cadmium after extraction of the metal into isobutyl methyl ketone containing 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide is described. The optimum extraction conditions were evaluated from a critical study of the effects of pH, concentration of extractant, shaking time and ionic strength. The detection limit for cadmium is 0.1 ng ml-1 and the calibration is linear from 0.2 to 140 ng ml-1. The relative standard deviation for ten replicate measurements is 2.9% for 2 ng ml-1 of cadmium. Results from the analysis of some certified biological reference materials are given.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An inductively coupled plasma atomic emission spectrometric method for the determination of trace amounts of cadmium after extraction of the metal into isobutyl methyl ketone containing 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide is described. The optimum extraction conditions were evaluated from a critical study of the effects of pH, concentration of extractant, shaking time and ionic strength. The detection limit for cadmium is 0.1 ng ml-1 and the calibration is linear from 0.2 to 140 ng ml-1. The relative standard deviation for ten replicate measurements is 2.9% for 2 ng ml-1 of cadmium. Results from the analysis of some certified biological reference materials are given.

Key concepts: Inductively coupled plasma, Extraction (chemistry), Cadmium, Chemistry, Inductively coupled plasma mass spectrometry, Analytical Chemistry (journal), Mass spectrometry, Plasma

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of cadmium in biological samples by inductively coupled plasma atomic emission spectrometry after extraction with 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide — Research Paper | ScholarLens