1974Zeitschrift für Naturforschung AOpen access

Precision Measurements of Magnetic Moments of Nuclei with weak NMR Signals

Wilfried Sahm, A. Schwenk

Open full text 55 citations

Abstract

Two NMR spectrometers were combined and a special probe assembly was constructed in order to enable a simultaneous measurement of the signals of 2H and any nucleus, the gyromagnetic ratio of which is <1.4·107T-1sec-1. The Larmor frequencies of 39K, 73Ge, and 109Ag in well defined samples were referred very accurately to the resonance of 2H in D2O. It was possible now, to refer the Lamor frequencies of the nuclei 41K, 57Fe, 87Sr, 107Ag, 183W, 187Os, which were previously referred to the resonance of one of the nuclei mentioned above, to the Larmor frequencies of the deuteron and the proton in D2O or H2O. The magnetic moments of all these nuclei are given.

Open-access reader

About this research paper

What this paper is about

Two NMR spectrometers were combined and a special probe assembly was constructed in order to enable a simultaneous measurement of the signals of 2H and any nucleus, the gyromagnetic ratio of which is <1.4·107T-1sec-1. The Larmor frequencies of 39K, 73Ge, and 109Ag in well defined samples were referred very accurately to the resonance of 2H in D2O. It was possible now, to refer the Lamor frequencies of the nuclei 41K, 57Fe, 87Sr, 107Ag, 183W, 187Os, which were previously referred to the resonance of one of the nuclei mentioned above, to the Larmor frequencies of the deuteron and the proton in D2O or H2O. The magnetic moments of all these nuclei are given.

Why it matters

OpenAlex reports 55 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Two NMR spectrometers were combined and a special probe assembly was constructed in order to enable a simultaneous measurement of the signals of 2H and any nucleus, the gyromagnetic ratio of which is <1.4·107T-1sec-1. The Larmor frequencies of 39K, 73Ge, and 109Ag in well defined samples were referred very accurately to the resonance of 2H in D2O. It was possible now, to refer the Lamor frequencies of the nuclei 41K, 57Fe, 87Sr, 107Ag, 183W, 187Os, which were previously referred to the resonance of one of the nuclei mentioned above, to the Larmor frequencies of the deuteron and the proton in D2O or H2O. The magnetic moments of all these nuclei are given.

Key concepts: Larmor precession, Gyromagnetic ratio, Nuclear magnetic resonance, Physics, Proton, Spectrometer, Resonance (particle physics), Atomic physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Precision Measurements of Magnetic Moments of Nuclei with weak NMR Signals — Research Paper | ScholarLens