Simultaneous Determination of the Volume of Red Cells and Plasma for Survival Studies of Stored Blood
Lawrence N. Button, John G. Gibson, Carl W. Walter
Abstract
Lawrence N. Button, John G. Gibson, Carl W. Walter
Abstract
A method is described for the determination of the in vivo survival of stored human red cells. Cr51 labeled red cells and I125 labeled human serum albumin are infused simultaneously to esti‐mate the whole blood volume and establish the 100 per cent retention value for subsequent red cell survival determination. The whole body hematocrit correction factor, necessary for the determination of 100 per cent retention value, has been established by the simul‐ taneous measurement of the red cell and plasma volumes in a group of 71 patients. Cr51 and I125 gamma emissions are separated for plasma and red cell volume determinations by measuring their values on a scaler equipped with a pulse height analyzer. This method has proven to be a safe and suitable means for the accurate establishment of in vivo survival of stored red cells, red cell mass, and plasma volume.
OpenAlex reports 46 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method is described for the determination of the in vivo survival of stored human red cells. Cr51 labeled red cells and I125 labeled human serum albumin are infused simultaneously to esti‐mate the whole blood volume and establish the 100 per cent retention value for subsequent red cell survival determination. The whole body hematocrit correction factor, necessary for the determination of 100 per cent retention value, has been established by the simul‐ taneous measurement of the red cell and plasma volumes in a group of 71 patients. Cr51 and I125 gamma emissions are separated for plasma and red cell volume determinations by measuring their values on a scaler equipped with a pulse height analyzer. This method has proven to be a safe and suitable means for the accurate establishment of in vivo survival of stored red cells, red cell mass, and plasma volume.
Key concepts: Hematocrit, Red Cell, Plasma volume, In vivo, Red blood cell, Volume (thermodynamics), Chemistry, Albumin