2014Indian Journal of OphthalmologyOpen access

Diurnal variation in central corneal thickness and intraocular pressure in eyes with pseudoexfoliation syndrome without glaucoma

Stuart Keel, Linda Malesic, Siew‐Pang Chan

Open full text 11 citations

Abstract

Aim: The aim was to ascertain if any differences exist in diurnal central corneal thickness (CCT) and intra-ocular pressure (IOP) between eyes with pseudoexfoliation (PXF) syndrome without glaucoma and eyes with no ocular pathology. A secondary aim was to determine whether there was a significant relationship between CCT and IOP. Settings and Design: This study was a prospective design conducted within a hospital setting. Materials and Methods: The experimental group consisted of seven participants with bilateral PXF (14 eyes) and the control group comprised of 15 participants (30 eyes). Testing included CCT and IOP measured at four different times on one given day (8.00 a.m.; 11 a.m.; 2 p.m. and 5 p.m.). Statistical Analysis: The data were analyzed with the generalized linear latent mixed model. Results: PXF eyes displayed a significantly thinner overall mean CCT (520 μm) compared to controls (530 μm). Furthermore, a significant reduction in CCT and IOP occurred in the PXF group from 8 a.m. to 5 p.m. The mean overall IOP in PXF eyes was significantly lower than the control group. A significant association between IOP and CCT was also found in PXF eyes. Conclusions: Displaying a significantly thinner mean CCT highlights the importance of measuring CCT in an ophthalmic clinical setting as to avoid falsely underestimated IOP measurements in such a high-risk glaucoma population. Furthermore, a statistically significant correlation between IOP and CCT in PXF eyes suggests that the reduction in CCT that occurred in PXF eyes between 8 a.m. and 5 p.m. may be partly responsible for the reduction in IOP measurements.

About this research paper

What this paper is about

Aim: The aim was to ascertain if any differences exist in diurnal central corneal thickness (CCT) and intra-ocular pressure (IOP) between eyes with pseudoexfoliation (PXF) syndrome without glaucoma and eyes with no ocular pathology. A secondary aim was to determine whether there was a significant relationship between CCT and IOP. Settings and Design: This study was a prospective design conducted within a hospital setting. Materials and Methods: The experimental group consisted of seven participants with bilateral PXF (14 eyes) and the control group comprised of 15 participants (30 eyes). Testing included CCT and IOP measured at four different times on one given day (8.00 a.m.; 11 a.m.; 2 p.m. and 5 p.m.). Statistical Analysis: The data were analyzed with the generalized linear latent mixed model. Results: PXF eyes displayed a significantly thinner overall mean CCT (520 μm) compared to controls (530 μm). Furthermore, a significant reduction in CCT and IOP occurred in the PXF group from 8 a.m. to 5 p.m. The mean overall IOP in PXF eyes was significantly lower than the control group. A significant association between IOP and CCT was also found in PXF eyes. Conclusions: Displaying a significantly thinner mean CCT highlights the importance of measuring CCT in an ophthalmic clinical setting as to avoid falsely underestimated IOP measurements in such a high-risk glaucoma population. Furthermore, a statistically significant correlation between IOP and CCT in PXF eyes suggests that the reduction in CCT that occurred in PXF eyes between 8 a.m. and 5 p.m. may be partly responsible for the reduction in IOP measurements.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim: The aim was to ascertain if any differences exist in diurnal central corneal thickness (CCT) and intra-ocular pressure (IOP) between eyes with pseudoexfoliation (PXF) syndrome without glaucoma and eyes with no ocular pathology. A secondary aim was to determine whether there was a significant relationship between CCT and IOP. Settings and Design: This study was a prospective design conducted within a hospital setting. Materials and Methods: The experimental group consisted of seven participants with bilateral PXF (14 eyes) and the control group comprised of 15 participants (30 eyes). Testing included CCT and IOP measured at four different times on one given day (8.00 a.m.; 11 a.m.; 2 p.m. and 5 p.m.). Statistical Analysis: The data were analyzed with the generalized linear latent mixed model. Results: PXF eyes displayed a significantly thinner overall mean CCT (520 μm) compared to controls (530 μm). Furthermore, a significant reduction in CCT and IOP occurred in the PXF group from 8 a.m. to 5 p.m. The mean overall IOP in PXF eyes was significantly lower than the control group. A significant association between IOP and CCT was also found in PXF eyes. Conclusions: Displaying a significantly thinner mean CCT highlights the importance of measuring CCT in an ophthalmic clinical setting as to avoid falsely underestimated IOP measurements in such a high-risk glaucoma population. Furthermore, a statistically significant correlation between IOP and CCT in PXF eyes suggests that the reduction in CCT that occurred in PXF eyes between 8 a.m. and 5 p.m. may be partly responsible for the reduction in IOP measurements.

Key concepts: Pseudoexfoliation syndrome, Glaucoma, Medicine, Intraocular pressure, Ophthalmology, Pseudoexfoliation, Optometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Diurnal variation in central corneal thickness and intraocular pressure in eyes with pseudoexfoliation syndrome without glaucoma — Research Paper | ScholarLens