1986Critical Care MedicineRequires access

Continuous Fick cardiac output compared to thermodilution cardiac output

Gerald G. Davies, Peter Jebson, Brian M. Glasgow, Douglas R. Hess

Open publisher page 49 citations

Abstract

A system has been developed to monitor continuously the components of the oxygen Fick equation: oxygen consumption by a gas exchange analyzer and arteriovenous oxygen difference by pulse and fiberoptic oximetry. A computer-based system was developed which calculates cardiac output and other variables every 20 sec. Continuous Fick (CF) cardiac output was compared to thermodilution (TD) cardiac output in 21 ventilated post-cardiac surgery patients. A total of 237 simultaneous cardiac output measurements had a range between 2 and 11 L/min. The correlation between CF and TD cardiac outputs was r = .86, with an equation of TD cardiac output = 0.92 CF cardiac output + 1.16. There was a significant (p less than .001) difference between the two methods of cardiac output estimation. The CF method was consistently lower than TD; this difference was greater at lower flows. CF cardiac output measurement is practical; it offers distinct advantages in viewing cardiac output together with oxygen demand and oxygen extraction.

About this research paper

What this paper is about

A system has been developed to monitor continuously the components of the oxygen Fick equation: oxygen consumption by a gas exchange analyzer and arteriovenous oxygen difference by pulse and fiberoptic oximetry. A computer-based system was developed which calculates cardiac output and other variables every 20 sec. Continuous Fick (CF) cardiac output was compared to thermodilution (TD) cardiac output in 21 ventilated post-cardiac surgery patients. A total of 237 simultaneous cardiac output measurements had a range between 2 and 11 L/min. The correlation between CF and TD cardiac outputs was r = .86, with an equation of TD cardiac output = 0.92 CF cardiac output + 1.16. There was a significant (p less than .001) difference between the two methods of cardiac output estimation. The CF method was consistently lower than TD; this difference was greater at lower flows. CF cardiac output measurement is practical; it offers distinct advantages in viewing cardiac output together with oxygen demand and oxygen extraction.

Why it matters

OpenAlex reports 49 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A system has been developed to monitor continuously the components of the oxygen Fick equation: oxygen consumption by a gas exchange analyzer and arteriovenous oxygen difference by pulse and fiberoptic oximetry. A computer-based system was developed which calculates cardiac output and other variables every 20 sec. Continuous Fick (CF) cardiac output was compared to thermodilution (TD) cardiac output in 21 ventilated post-cardiac surgery patients. A total of 237 simultaneous cardiac output measurements had a range between 2 and 11 L/min. The correlation between CF and TD cardiac outputs was r = .86, with an equation of TD cardiac output = 0.92 CF cardiac output + 1.16. There was a significant (p less than .001) difference between the two methods of cardiac output estimation. The CF method was consistently lower than TD; this difference was greater at lower flows. CF cardiac output measurement is practical; it offers distinct advantages in viewing cardiac output together with oxygen demand and oxygen extraction.

Key concepts: Cardiac output, Fick principle, Medicine, Cardiac surgery, Cardiology, Oxygen, Internal medicine, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Continuous Fick cardiac output compared to thermodilution cardiac output — Research Paper | ScholarLens