1989Biomedical ChromatographyRequires access

High performance liquid chromatography determination of cyanide in urine by pre‐column fluorescence derivatization

Akira Sano, Masaaki Takezawa, Shoji Takitani

Open publisher page 30 citations

Abstract

A method for the determination of cyanide in human urine has been developed. The method is based on the reaction of cyanide with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product for reversed-phase HPLC separation and fluorometric detection. After centrifugation followed by dilution of urine samples, the specimens could be analysed directly by this method. The recovery of cyanide added to urine at concentration levels of 50-1000 pmol/mL was 85-96%. The detection limit of cyanide was 30 pmol/mL in urine. The method was successfully applied to the analysis of urine from smokers and nonsmokers. The mean concentrations of cyanide were found to be 215 pmol/mL for the former and 84 pmol/mL for the latter.

About this research paper

What this paper is about

A method for the determination of cyanide in human urine has been developed. The method is based on the reaction of cyanide with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product for reversed-phase HPLC separation and fluorometric detection. After centrifugation followed by dilution of urine samples, the specimens could be analysed directly by this method. The recovery of cyanide added to urine at concentration levels of 50-1000 pmol/mL was 85-96%. The detection limit of cyanide was 30 pmol/mL in urine. The method was successfully applied to the analysis of urine from smokers and nonsmokers. The mean concentrations of cyanide were found to be 215 pmol/mL for the former and 84 pmol/mL for the latter.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of cyanide in human urine has been developed. The method is based on the reaction of cyanide with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product for reversed-phase HPLC separation and fluorometric detection. After centrifugation followed by dilution of urine samples, the specimens could be analysed directly by this method. The recovery of cyanide added to urine at concentration levels of 50-1000 pmol/mL was 85-96%. The detection limit of cyanide was 30 pmol/mL in urine. The method was successfully applied to the analysis of urine from smokers and nonsmokers. The mean concentrations of cyanide were found to be 215 pmol/mL for the former and 84 pmol/mL for the latter.

Key concepts: Chemistry, Chromatography, Cyanide, Derivatization, Urine, Detection limit, High-performance liquid chromatography, Dilution

Related papers

Back to paper searchBrowse research topicsOriginal source
High performance liquid chromatography determination of cyanide in urine by pre‐column fluorescence derivatization — Research Paper | ScholarLens