2011Volume 4: Energy Systems Analysis, Thermodynamics and Sustainability; Combustion Science and Engineering; Nanoengineering for Energy, Parts A and BRequires access

In-Situ Thermal Response Test for Ground Source Heat Pump Application

Wenzhi Cui, Quan Liao, Guiqin Chang, Qingyuan Peng, Tien‐Chien Jen

Open publisher page 0 citations

Abstract

The design and performance optimization of ground source heat pump (GSHP) systems need the exact thermal properties of the soil, such as ground thermal conductivity and capacity, and the borehole thermal resistance of borehole heat exchanger (BHE). In-situ thermal response test (TRT) is the most widely used method to determine the overall thermal physical properties of the geological structure around the borehole. A TRT experimental apparatus has been developed and thermal response test was performed in Chongqing, southwest China. Both single-U and double-U borehole heat exchangers are studied in this work. The test duration is about 70 hours. Data direct fitting and parameter estimate method are both used to determine the soil thermal conductivity and the borehole thermal resistance. The results showed that the average ground thermal conductivity of the test region for single U and double U BHE conditions are 2.55 and 2.51 Wm−1K−1, and borehole thermal resistance are 0.116 and 0.066 mKW−1, respectively.

About this research paper

What this paper is about

The design and performance optimization of ground source heat pump (GSHP) systems need the exact thermal properties of the soil, such as ground thermal conductivity and capacity, and the borehole thermal resistance of borehole heat exchanger (BHE). In-situ thermal response test (TRT) is the most widely used method to determine the overall thermal physical properties of the geological structure around the borehole. A TRT experimental apparatus has been developed and thermal response test was performed in Chongqing, southwest China. Both single-U and double-U borehole heat exchangers are studied in this work. The test duration is about 70 hours. Data direct fitting and parameter estimate method are both used to determine the soil thermal conductivity and the borehole thermal resistance. The results showed that the average ground thermal conductivity of the test region for single U and double U BHE conditions are 2.55 and 2.51 Wm−1K−1, and borehole thermal resistance are 0.116 and 0.066 mKW−1, respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The design and performance optimization of ground source heat pump (GSHP) systems need the exact thermal properties of the soil, such as ground thermal conductivity and capacity, and the borehole thermal resistance of borehole heat exchanger (BHE). In-situ thermal response test (TRT) is the most widely used method to determine the overall thermal physical properties of the geological structure around the borehole. A TRT experimental apparatus has been developed and thermal response test was performed in Chongqing, southwest China. Both single-U and double-U borehole heat exchangers are studied in this work. The test duration is about 70 hours. Data direct fitting and parameter estimate method are both used to determine the soil thermal conductivity and the borehole thermal resistance. The results showed that the average ground thermal conductivity of the test region for single U and double U BHE conditions are 2.55 and 2.51 Wm−1K−1, and borehole thermal resistance are 0.116 and 0.066 mKW−1, respectively.

Key concepts: Borehole, Thermal conductivity, Heat pump, Heat exchanger, Thermal resistance, Thermal, Materials science, Thermal effusivity