BACKGROUND/AIMS: This study attempted to establish carotid ultrasound criteria for identifying stenosis of the intracranial internal carotid artery (ICA) and middle cerebral artery (MCA). METHODS: Two hundred and fifty-five patients were enrolled. Ultrasound measurements for common carotid artery (CCA) and ICA were as follows: flow volume (FV), peak systolic velocity (PSV), end-diastolic velocity (EDV), pulsatility index (PI) and resistance index (RI). The sensitivity and specificity of the ultrasound criteria for determining intracranial ICA or MCA>or=50% stenosis were calculated. RESULTS: The criteria identified for detecting intracranial ICA>or=50% stenosis were ICA FV<159 ml/min, ICA PSV<33 cm/s and CCA PSV<42 cm/s. When ICA PSV<33 cm/s was combined with CCA PSV<42 cm/s, sensitivity increased to 82%, with 91% specificity. The criteria identified for detecting MCA>or=50% stenosis were CCA FV<285 ml/min, ICA FV<179 ml/min, ICA PSV<33 cm/s, >35% reduction in FV in the CCA, >40% reduction in FV in ICA, and >35% reduction in PSV in ICA. When these criteria were combined, sensitivity increased to 69%, with 85% specificity. CONCLUSION: This study demonstrated that ultrasound criteria are sensitive and specific for detecting intracranial ICA and MCA significant obstruction.

About this research paper

What this paper is about

BACKGROUND/AIMS: This study attempted to establish carotid ultrasound criteria for identifying stenosis of the intracranial internal carotid artery (ICA) and middle cerebral artery (MCA). METHODS: Two hundred and fifty-five patients were enrolled. Ultrasound measurements for common carotid artery (CCA) and ICA were as follows: flow volume (FV), peak systolic velocity (PSV), end-diastolic velocity (EDV), pulsatility index (PI) and resistance index (RI). The sensitivity and specificity of the ultrasound criteria for determining intracranial ICA or MCA>or=50% stenosis were calculated. RESULTS: The criteria identified for detecting intracranial ICA>or=50% stenosis were ICA FV<159 ml/min, ICA PSV<33 cm/s and CCA PSV<42 cm/s. When ICA PSV<33 cm/s was combined with CCA PSV<42 cm/s, sensitivity increased to 82%, with 91% specificity. The criteria identified for detecting MCA>or=50% stenosis were CCA FV<285 ml/min, ICA FV<179 ml/min, ICA PSV<33 cm/s, >35% reduction in FV in the CCA, >40% reduction in FV in ICA, and >35% reduction in PSV in ICA. When these criteria were combined, sensitivity increased to 69%, with 85% specificity. CONCLUSION: This study demonstrated that ultrasound criteria are sensitive and specific for detecting intracranial ICA and MCA significant obstruction.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND/AIMS: This study attempted to establish carotid ultrasound criteria for identifying stenosis of the intracranial internal carotid artery (ICA) and middle cerebral artery (MCA). METHODS: Two hundred and fifty-five patients were enrolled. Ultrasound measurements for common carotid artery (CCA) and ICA were as follows: flow volume (FV), peak systolic velocity (PSV), end-diastolic velocity (EDV), pulsatility index (PI) and resistance index (RI). The sensitivity and specificity of the ultrasound criteria for determining intracranial ICA or MCA>or=50% stenosis were calculated. RESULTS: The criteria identified for detecting intracranial ICA>or=50% stenosis were ICA FV<159 ml/min, ICA PSV<33 cm/s and CCA PSV<42 cm/s. When ICA PSV<33 cm/s was combined with CCA PSV<42 cm/s, sensitivity increased to 82%, with 91% specificity. The criteria identified for detecting MCA>or=50% stenosis were CCA FV<285 ml/min, ICA FV<179 ml/min, ICA PSV<33 cm/s, >35% reduction in FV in the CCA, >40% reduction in FV in ICA, and >35% reduction in PSV in ICA. When these criteria were combined, sensitivity increased to 69%, with 85% specificity. CONCLUSION: This study demonstrated that ultrasound criteria are sensitive and specific for detecting intracranial ICA and MCA significant obstruction.

Key concepts: Stenosis, Medicine, Ultrasound, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Carotid Ultrasound Criteria for Detecting Intracranial Carotid Stenosis — Research Paper | ScholarLens