Determination of alkylphenols and their short-chained ethoxylates in Polish river waters
Agnieszka Zgoła‐Grześkowiak, Tomasz Grześkowiak
Abstract
Agnieszka Zgoła‐Grześkowiak, Tomasz Grześkowiak
Abstract
A simple and robust analytical method for analysis of octyl- and nonylphenol as well as their short-chained ethoxylates in river water was proposed. Quantification of these analytes was performed by high-performance liquid chromatography with fluorescence detection after isolation using solid phase extraction with polytetrafluoroethylene sorbent. The method allowed one to obtain about 80–100% recovery for octylphenol and its ethoxylates and 70–80% for nonylphenol and its ethoxylates. Also, there was no need for additional sample cleaning before chromatographic analysis. The limit of detection was 0.01 µg L−1 for octylphenol and its ethoxylates and 0.03 µg L−1 for nonylphenol and its ethoxylates. The proposed method was used for quantitation of octyl- and nonylphenol together with their short-chained ethoxylates. Nonylphenol, nonylphenol mono- and diethoxylates were detected at concentrations ranging from 0.12 to 0.53 µg L−1. Octylphenol, octylphenol mono- and diethoxylates were detected in four out of eleven samples at concentrations ranging from 0.03 to 0.17 µg L−1. High concentrations of nonylphenol and its ethoxylates were found in the samples, despite the fact that their use in European countries was forbidden several years ago.
OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple and robust analytical method for analysis of octyl- and nonylphenol as well as their short-chained ethoxylates in river water was proposed. Quantification of these analytes was performed by high-performance liquid chromatography with fluorescence detection after isolation using solid phase extraction with polytetrafluoroethylene sorbent. The method allowed one to obtain about 80–100% recovery for octylphenol and its ethoxylates and 70–80% for nonylphenol and its ethoxylates. Also, there was no need for additional sample cleaning before chromatographic analysis. The limit of detection was 0.01 µg L−1 for octylphenol and its ethoxylates and 0.03 µg L−1 for nonylphenol and its ethoxylates. The proposed method was used for quantitation of octyl- and nonylphenol together with their short-chained ethoxylates. Nonylphenol, nonylphenol mono- and diethoxylates were detected at concentrations ranging from 0.12 to 0.53 µg L−1. Octylphenol, octylphenol mono- and diethoxylates were detected in four out of eleven samples at concentrations ranging from 0.03 to 0.17 µg L−1. High concentrations of nonylphenol and its ethoxylates were found in the samples, despite the fact that their use in European countries was forbidden several years ago.
Key concepts: Nonylphenol, Chromatography, Extraction (chemistry), Alkylphenol, Chemistry, Solid phase extraction, Environmental chemistry, Organic chemistry