1977Journal of Speech and Hearing ResearchRequires access

A Comparison of Four Hearing Aid Measurement Systems

Thomas H. Townsend, Daniel M. Schwartz

Open publisher page 0 citations

Abstract

Measurements of hearing aid performance were made using four different electroacoustic systems. Nine hearing aids were evaluated three times in each of the four systems: a standard Bruel and Kjaer apparatus, a Fonix 5000, and both a Phonic Ear HC 1000 and HC 2000. Tests included frequency response and, when possible, total harmonic distortion, second harmonic distortion, and third harmonic distortion. Results were equivalent for frequency response and second harmonic distortion, whereas significant differences occurred for total harmonic distortion and third harmonic distortion at both the low and high frequencies. The degree to which the sum of second harmonic distortion and third harmonic distortion fails to equal the total harmonic distortion was also examined. In the low frequency region, second harmonic distortion plus third harmonic distortion yielded values considerably less than the total harmonic distortion, although good agreement was found in the midfrequencies.

About this research paper

What this paper is about

Measurements of hearing aid performance were made using four different electroacoustic systems. Nine hearing aids were evaluated three times in each of the four systems: a standard Bruel and Kjaer apparatus, a Fonix 5000, and both a Phonic Ear HC 1000 and HC 2000. Tests included frequency response and, when possible, total harmonic distortion, second harmonic distortion, and third harmonic distortion. Results were equivalent for frequency response and second harmonic distortion, whereas significant differences occurred for total harmonic distortion and third harmonic distortion at both the low and high frequencies. The degree to which the sum of second harmonic distortion and third harmonic distortion fails to equal the total harmonic distortion was also examined. In the low frequency region, second harmonic distortion plus third harmonic distortion yielded values considerably less than the total harmonic distortion, although good agreement was found in the midfrequencies.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Measurements of hearing aid performance were made using four different electroacoustic systems. Nine hearing aids were evaluated three times in each of the four systems: a standard Bruel and Kjaer apparatus, a Fonix 5000, and both a Phonic Ear HC 1000 and HC 2000. Tests included frequency response and, when possible, total harmonic distortion, second harmonic distortion, and third harmonic distortion. Results were equivalent for frequency response and second harmonic distortion, whereas significant differences occurred for total harmonic distortion and third harmonic distortion at both the low and high frequencies. The degree to which the sum of second harmonic distortion and third harmonic distortion fails to equal the total harmonic distortion was also examined. In the low frequency region, second harmonic distortion plus third harmonic distortion yielded values considerably less than the total harmonic distortion, although good agreement was found in the midfrequencies.

Key concepts: Total harmonic distortion, Distortion (music), THD analyzer, Harmonic, Acoustics, Amplitude distortion, Nonlinear distortion, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
A Comparison of Four Hearing Aid Measurement Systems — Research Paper | ScholarLens