1997Acta Obstetricia Et Gynecologica ScandinavicaRequires access

Enhanced separation of X and Y bearing sperm cells by a combined density gradient centrifugation evaluated by fluorescence in situ hybridization of the Y‐chromosome

Claus Yding Andersen, Anne Grete Byskov

Open publisher page 14 citations

Abstract

OBJECTIVES: Fluorescent in situ hybridization of decondensed sperm cells was used to evaluate the effectiveness of separating X- and Y chromosome bearing sperm cells using a combination of Percoll and NycoPrep media. MATERIAL AND METHODS: Semen samples from seven healthy men were divided into three equal aliquots. One aliquot served as an untreated control, the other two were either applied to a seven-step Percoll gradient (100%-40%), or to a seven-step Percoll gradient (100%-40%) underlayered with 100% NycoPrep for sperm purification. After centrifugation Y-bearing sperm cells in the pellet and in the control sample was determined by fluorescent in situ hybridization. RESULTS: A significantly reduction of Y-bearing sperm cells were observed in the pellet of the Percoll + NycoPrep centrifugation (39.3% Y-bearing sperm cells) compared to the control sample and to Percoll centrifugation without NycoPrep. The Percoll centrifugation without NycoPrep did not show a significant reduction of Y-bearing sperm cells in the pellet compared to the control sample. CONCLUSION: By the addition of a medium with a density higher than 100% Percoll a significantly increased separation of X and Y-bearing sperm cells can be achieved. This study opens new perspectives for improving separation of X- and Y-bearing spermatozoa by simple centrifugations. The described centrifugation technique can be applied in connection with preimplantation diagnosis in order to create more pre-embryos of the desired gender.

About this research paper

What this paper is about

OBJECTIVES: Fluorescent in situ hybridization of decondensed sperm cells was used to evaluate the effectiveness of separating X- and Y chromosome bearing sperm cells using a combination of Percoll and NycoPrep media. MATERIAL AND METHODS: Semen samples from seven healthy men were divided into three equal aliquots. One aliquot served as an untreated control, the other two were either applied to a seven-step Percoll gradient (100%-40%), or to a seven-step Percoll gradient (100%-40%) underlayered with 100% NycoPrep for sperm purification. After centrifugation Y-bearing sperm cells in the pellet and in the control sample was determined by fluorescent in situ hybridization. RESULTS: A significantly reduction of Y-bearing sperm cells were observed in the pellet of the Percoll + NycoPrep centrifugation (39.3% Y-bearing sperm cells) compared to the control sample and to Percoll centrifugation without NycoPrep. The Percoll centrifugation without NycoPrep did not show a significant reduction of Y-bearing sperm cells in the pellet compared to the control sample. CONCLUSION: By the addition of a medium with a density higher than 100% Percoll a significantly increased separation of X and Y-bearing sperm cells can be achieved. This study opens new perspectives for improving separation of X- and Y-bearing spermatozoa by simple centrifugations. The described centrifugation technique can be applied in connection with preimplantation diagnosis in order to create more pre-embryos of the desired gender.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: Fluorescent in situ hybridization of decondensed sperm cells was used to evaluate the effectiveness of separating X- and Y chromosome bearing sperm cells using a combination of Percoll and NycoPrep media. MATERIAL AND METHODS: Semen samples from seven healthy men were divided into three equal aliquots. One aliquot served as an untreated control, the other two were either applied to a seven-step Percoll gradient (100%-40%), or to a seven-step Percoll gradient (100%-40%) underlayered with 100% NycoPrep for sperm purification. After centrifugation Y-bearing sperm cells in the pellet and in the control sample was determined by fluorescent in situ hybridization. RESULTS: A significantly reduction of Y-bearing sperm cells were observed in the pellet of the Percoll + NycoPrep centrifugation (39.3% Y-bearing sperm cells) compared to the control sample and to Percoll centrifugation without NycoPrep. The Percoll centrifugation without NycoPrep did not show a significant reduction of Y-bearing sperm cells in the pellet compared to the control sample. CONCLUSION: By the addition of a medium with a density higher than 100% Percoll a significantly increased separation of X and Y-bearing sperm cells can be achieved. This study opens new perspectives for improving separation of X- and Y-bearing spermatozoa by simple centrifugations. The described centrifugation technique can be applied in connection with preimplantation diagnosis in order to create more pre-embryos of the desired gender.

Key concepts: Percoll, Sperm, Centrifugation, Differential centrifugation, Semen, Andrology, Molecular biology, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Enhanced separation of X and Y bearing sperm cells by a combined density gradient centrifugation evaluated by fluorescence in situ hybridization of the Y‐chromosome — Research Paper | ScholarLens