2010Journal of Diabetes Science and TechnologyOpen access

Predictors of Initiating Rapid-Acting Insulin Analog Using Vial/Syringe, Prefilled Pen, and Reusable Pen Devices in Patients with Type 2 Diabetes

Lauren J. Lee, Julie A. Anderson, Shonda A. Foster, Sheila M. Corrigan, David M. Smith, Suellen M. Curkendall

Open full text 6 citations

Abstract

BACKGROUND: Limited data are available on the predictors of insulin delivery device choice. This study assessed the patient- and health-care-system-related factors that predict the initiation of one rapid-acting insulin analog (RAIA) delivery system over another. METHODS: A retrospective analysis using a claims database (January 1, 2007, through March 31, 2009) was conducted. Patients were required to be diagnosed with type 2 diabetes mellitus, and have >or=12 months of continuous eligibility prior to their first prescription of a RAIA on or after January 1, 2008. The three cohorts in the study were vial/syringe (n = 6820), prefilled pen (n = 5840), and reusable pen (n = 2052). Multiple factors were examined using stepwise logistic regression. RESULTS: Factors that increased the likelihood of initiating RAIA using prefilled pen versus vial/syringe included endocrinologist visit [odds ratio (OR) = 3.13, 95% confidence interval (CI) = 2.56, 3.82], prior basal insulin use with pen (OR = 4.85, 95% CI = 4.21, 5.59), and use of >or=1 oral antihyperglycemic agents (OR = 1.32, 95% CI = 1.20, 1.45). Factors that decreased the likelihood included inpatient admission (OR = 0.76, 95% CI = 0.70, 0.83), nursing home visit (OR = 0.22, 95% CI = 0.18, 0.27), and obesity (OR = 0.67, 95% CI = 0.53, 0.83). There were fewer differences between prefilled and reusable pen initiators. Factors that increased the likelihood of initiating with prefilled versus reusable pen included endocrinologist visit (OR = 1.87, CI = 1.50, 2.34) and inpatient admission (OR = 1.46, 95% CI = 1.30, 1.64). CONCLUSION: Significant differences in predictors were observed between prefilled pen and vial/syringe initiators. The differences were fewer between prefilled and reusable pen initiators. These differences should be taken into consideration when evaluating outcomes associated with specific insulin delivery systems.

About this research paper

What this paper is about

BACKGROUND: Limited data are available on the predictors of insulin delivery device choice. This study assessed the patient- and health-care-system-related factors that predict the initiation of one rapid-acting insulin analog (RAIA) delivery system over another. METHODS: A retrospective analysis using a claims database (January 1, 2007, through March 31, 2009) was conducted. Patients were required to be diagnosed with type 2 diabetes mellitus, and have >or=12 months of continuous eligibility prior to their first prescription of a RAIA on or after January 1, 2008. The three cohorts in the study were vial/syringe (n = 6820), prefilled pen (n = 5840), and reusable pen (n = 2052). Multiple factors were examined using stepwise logistic regression. RESULTS: Factors that increased the likelihood of initiating RAIA using prefilled pen versus vial/syringe included endocrinologist visit [odds ratio (OR) = 3.13, 95% confidence interval (CI) = 2.56, 3.82], prior basal insulin use with pen (OR = 4.85, 95% CI = 4.21, 5.59), and use of >or=1 oral antihyperglycemic agents (OR = 1.32, 95% CI = 1.20, 1.45). Factors that decreased the likelihood included inpatient admission (OR = 0.76, 95% CI = 0.70, 0.83), nursing home visit (OR = 0.22, 95% CI = 0.18, 0.27), and obesity (OR = 0.67, 95% CI = 0.53, 0.83). There were fewer differences between prefilled and reusable pen initiators. Factors that increased the likelihood of initiating with prefilled versus reusable pen included endocrinologist visit (OR = 1.87, CI = 1.50, 2.34) and inpatient admission (OR = 1.46, 95% CI = 1.30, 1.64). CONCLUSION: Significant differences in predictors were observed between prefilled pen and vial/syringe initiators. The differences were fewer between prefilled and reusable pen initiators. These differences should be taken into consideration when evaluating outcomes associated with specific insulin delivery systems.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Limited data are available on the predictors of insulin delivery device choice. This study assessed the patient- and health-care-system-related factors that predict the initiation of one rapid-acting insulin analog (RAIA) delivery system over another. METHODS: A retrospective analysis using a claims database (January 1, 2007, through March 31, 2009) was conducted. Patients were required to be diagnosed with type 2 diabetes mellitus, and have >or=12 months of continuous eligibility prior to their first prescription of a RAIA on or after January 1, 2008. The three cohorts in the study were vial/syringe (n = 6820), prefilled pen (n = 5840), and reusable pen (n = 2052). Multiple factors were examined using stepwise logistic regression. RESULTS: Factors that increased the likelihood of initiating RAIA using prefilled pen versus vial/syringe included endocrinologist visit [odds ratio (OR) = 3.13, 95% confidence interval (CI) = 2.56, 3.82], prior basal insulin use with pen (OR = 4.85, 95% CI = 4.21, 5.59), and use of >or=1 oral antihyperglycemic agents (OR = 1.32, 95% CI = 1.20, 1.45). Factors that decreased the likelihood included inpatient admission (OR = 0.76, 95% CI = 0.70, 0.83), nursing home visit (OR = 0.22, 95% CI = 0.18, 0.27), and obesity (OR = 0.67, 95% CI = 0.53, 0.83). There were fewer differences between prefilled and reusable pen initiators. Factors that increased the likelihood of initiating with prefilled versus reusable pen included endocrinologist visit (OR = 1.87, CI = 1.50, 2.34) and inpatient admission (OR = 1.46, 95% CI = 1.30, 1.64). CONCLUSION: Significant differences in predictors were observed between prefilled pen and vial/syringe initiators. The differences were fewer between prefilled and reusable pen initiators. These differences should be taken into consideration when evaluating outcomes associated with specific insulin delivery systems.

Key concepts: Syringe, Vial, Insulin pen, Medicine, Insulin, Type 2 diabetes, Type 1 diabetes, Diabetes mellitus

Related papers

Back to paper searchBrowse research topicsOriginal source
Predictors of Initiating Rapid-Acting Insulin Analog Using Vial/Syringe, Prefilled Pen, and Reusable Pen Devices in Patients with Type 2 Diabetes — Research Paper | ScholarLens