2010Unpublished venueRequires access

Comparison between Ramp Pulse Modulation (RPM) and constant frequency modulation for the beat frequency oscillation in voltage regulators

Kisun Lee, Han Zou

Open publisher page 15 citations

Abstract

In the voltage regulator (VR) applications, the load frequency varies in a very wide range from several kHz to several MHz. When the load transient frequency approaches to the switching frequency of VR, there is a low frequency oscillation in the system, which is the beat frequency oscillation between the load transient frequency and the switching frequency of VR. When this low frequency oscillation becomes significant, the system may be hurt. The root cause of this beat frequency oscillation is constant frequency operation of the VR. In order to resolve this problem, Ramp Pulse Modulation (RPM) method is proposed. A Ramp Pulse Modulation control is one of the ripple based control methods, which is generally used in the single phase voltage regulators. In this paper, RPM method is reviewed and it is compared to the constant frequency control method with experiments.

About this research paper

What this paper is about

In the voltage regulator (VR) applications, the load frequency varies in a very wide range from several kHz to several MHz. When the load transient frequency approaches to the switching frequency of VR, there is a low frequency oscillation in the system, which is the beat frequency oscillation between the load transient frequency and the switching frequency of VR. When this low frequency oscillation becomes significant, the system may be hurt. The root cause of this beat frequency oscillation is constant frequency operation of the VR. In order to resolve this problem, Ramp Pulse Modulation (RPM) method is proposed. A Ramp Pulse Modulation control is one of the ripple based control methods, which is generally used in the single phase voltage regulators. In this paper, RPM method is reviewed and it is compared to the constant frequency control method with experiments.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the voltage regulator (VR) applications, the load frequency varies in a very wide range from several kHz to several MHz. When the load transient frequency approaches to the switching frequency of VR, there is a low frequency oscillation in the system, which is the beat frequency oscillation between the load transient frequency and the switching frequency of VR. When this low frequency oscillation becomes significant, the system may be hurt. The root cause of this beat frequency oscillation is constant frequency operation of the VR. In order to resolve this problem, Ramp Pulse Modulation (RPM) method is proposed. A Ramp Pulse Modulation control is one of the ripple based control methods, which is generally used in the single phase voltage regulators. In this paper, RPM method is reviewed and it is compared to the constant frequency control method with experiments.

Key concepts: Pulse-frequency modulation, Frequency modulation, Oscillation (cell signaling), Voltage-controlled oscillator, Ripple, Control theory (sociology), Pulse-width modulation, Frequency deviation

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison between Ramp Pulse Modulation (RPM) and constant frequency modulation for the beat frequency oscillation in voltage regulators — Research Paper | ScholarLens