2008Journal of Applied PhysicsOpen access

Inexpensive acoustoelectric hydrophone for mapping high intensity ultrasonic fields

Russell S. Witte, Tim Hall, Ragnar Olafsson, Sheng-Wen Huang, Matthew O’Donnell

Open full text 8 citations

Abstract

We describe an inexpensive alternative to conventional hydrophones for measuring ultrasonic fields. The hydrophone, composed of common laboratory supplies, depends on the acoustoelectric (AE) effect, a well-known interaction between electrical current and pressure. Beam patterns of a 540 kHz annular transducer captured using a bowtie graphite hydrophone were consistent with patterns obtained using conventional, more expensive hydrophones. The AE signal was proportional to both the applied bias current (1.83 µV/mA) and pressure (13.3 µV/MPa) with sensitivity better than 50 kPa. Disposable AE hydrophones may be an attractive alternative for clinical applications that require close monitoring of high intensity acoustic fields.

About this research paper

What this paper is about

We describe an inexpensive alternative to conventional hydrophones for measuring ultrasonic fields. The hydrophone, composed of common laboratory supplies, depends on the acoustoelectric (AE) effect, a well-known interaction between electrical current and pressure. Beam patterns of a 540 kHz annular transducer captured using a bowtie graphite hydrophone were consistent with patterns obtained using conventional, more expensive hydrophones. The AE signal was proportional to both the applied bias current (1.83 µV/mA) and pressure (13.3 µV/MPa) with sensitivity better than 50 kPa. Disposable AE hydrophones may be an attractive alternative for clinical applications that require close monitoring of high intensity acoustic fields.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We describe an inexpensive alternative to conventional hydrophones for measuring ultrasonic fields. The hydrophone, composed of common laboratory supplies, depends on the acoustoelectric (AE) effect, a well-known interaction between electrical current and pressure. Beam patterns of a 540 kHz annular transducer captured using a bowtie graphite hydrophone were consistent with patterns obtained using conventional, more expensive hydrophones. The AE signal was proportional to both the applied bias current (1.83 µV/mA) and pressure (13.3 µV/MPa) with sensitivity better than 50 kPa. Disposable AE hydrophones may be an attractive alternative for clinical applications that require close monitoring of high intensity acoustic fields.

Key concepts: Hydrophone, Acoustics, Ultrasonic sensor, Transducer, SIGNAL (programming language), Materials science, Sensitivity (control systems), Sound pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
Inexpensive acoustoelectric hydrophone for mapping high intensity ultrasonic fields — Research Paper | ScholarLens