2012Journal of Refractive SurgeryRequires access

Residual Astigmatism Following Toric Intraocular Lens Implantation Related to Pupil Size

Nienke Visser, Noël J.C. Bauer, Rudy M.M.A. Nuijts

Open publisher page 45 citations

Abstract

PURPOSE: To present two patients with residual astigmatism following toric intraocular lens (IOL) implantation. METHODS: Case reports. RESULTS: A 58-year-old woman underwent toric IOL implantation (spherical power 29.50 diopters [D], cylinder power 3.00 D; SN60T5, Alcon Laboratories Inc) to correct 2.33 D @ 80° of corneal astigmatism. Postoperatively, uncorrected distance visual acuity (UDVA) was 20/30 and corrected distance visual acuity (CDVA) was 20/22 (0 -1.75 × 95), indicating an overcorrection of astigmatism. Slit-lamp examination demonstrated no IOL misalignment. Wavefront aberrometry showed a large pupil diameter (>6 mm) and a lower corneal astigmatism in a 6-mm zone (-1.40 D @ 174°) compared to a 4-mm zone (-2.21 D @ 171°). The second patient, a 60-year-old man, underwent multifocal toric IOL implantation (spherical power 22.50 D, cylinder power 2.25 D; SND1T4, Alcon Laboratories Inc) to correct 1.51 D @ 173° of corneal astigmatism. Postoperatively, UDVA was 20/50 and CDVA was 20/20 (+0.25 -1.00 × 102), indicating an undercorrection of astigmatism. Slit-lamp examination showed no misalignment. CONCLUSIONS: Both cases indicate that unexplained residual astigmatism following toric IOL implantation may be the result of multiple factors: the effect of the spherical power and anterior chamber depth on toric IOL calculations, the effect of posterior corneal astigmatism, and the effect of a large pupil size. The first two issues may be compensated for by improving toric IOL calculations. The latter indicates that pupillometry is indicated in relatively young patients who undergo toric IOL implantation.

About this research paper

What this paper is about

PURPOSE: To present two patients with residual astigmatism following toric intraocular lens (IOL) implantation. METHODS: Case reports. RESULTS: A 58-year-old woman underwent toric IOL implantation (spherical power 29.50 diopters [D], cylinder power 3.00 D; SN60T5, Alcon Laboratories Inc) to correct 2.33 D @ 80° of corneal astigmatism. Postoperatively, uncorrected distance visual acuity (UDVA) was 20/30 and corrected distance visual acuity (CDVA) was 20/22 (0 -1.75 × 95), indicating an overcorrection of astigmatism. Slit-lamp examination demonstrated no IOL misalignment. Wavefront aberrometry showed a large pupil diameter (>6 mm) and a lower corneal astigmatism in a 6-mm zone (-1.40 D @ 174°) compared to a 4-mm zone (-2.21 D @ 171°). The second patient, a 60-year-old man, underwent multifocal toric IOL implantation (spherical power 22.50 D, cylinder power 2.25 D; SND1T4, Alcon Laboratories Inc) to correct 1.51 D @ 173° of corneal astigmatism. Postoperatively, UDVA was 20/50 and CDVA was 20/20 (+0.25 -1.00 × 102), indicating an undercorrection of astigmatism. Slit-lamp examination showed no misalignment. CONCLUSIONS: Both cases indicate that unexplained residual astigmatism following toric IOL implantation may be the result of multiple factors: the effect of the spherical power and anterior chamber depth on toric IOL calculations, the effect of posterior corneal astigmatism, and the effect of a large pupil size. The first two issues may be compensated for by improving toric IOL calculations. The latter indicates that pupillometry is indicated in relatively young patients who undergo toric IOL implantation.

Why it matters

OpenAlex reports 45 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To present two patients with residual astigmatism following toric intraocular lens (IOL) implantation. METHODS: Case reports. RESULTS: A 58-year-old woman underwent toric IOL implantation (spherical power 29.50 diopters [D], cylinder power 3.00 D; SN60T5, Alcon Laboratories Inc) to correct 2.33 D @ 80° of corneal astigmatism. Postoperatively, uncorrected distance visual acuity (UDVA) was 20/30 and corrected distance visual acuity (CDVA) was 20/22 (0 -1.75 × 95), indicating an overcorrection of astigmatism. Slit-lamp examination demonstrated no IOL misalignment. Wavefront aberrometry showed a large pupil diameter (>6 mm) and a lower corneal astigmatism in a 6-mm zone (-1.40 D @ 174°) compared to a 4-mm zone (-2.21 D @ 171°). The second patient, a 60-year-old man, underwent multifocal toric IOL implantation (spherical power 22.50 D, cylinder power 2.25 D; SND1T4, Alcon Laboratories Inc) to correct 1.51 D @ 173° of corneal astigmatism. Postoperatively, UDVA was 20/50 and CDVA was 20/20 (+0.25 -1.00 × 102), indicating an undercorrection of astigmatism. Slit-lamp examination showed no misalignment. CONCLUSIONS: Both cases indicate that unexplained residual astigmatism following toric IOL implantation may be the result of multiple factors: the effect of the spherical power and anterior chamber depth on toric IOL calculations, the effect of posterior corneal astigmatism, and the effect of a large pupil size. The first two issues may be compensated for by improving toric IOL calculations. The latter indicates that pupillometry is indicated in relatively young patients who undergo toric IOL implantation.

Key concepts: Astigmatism, Dioptre, Ophthalmology, Intraocular lens, Pupil, Medicine, Corneal topography, Refractive error

Related papers

Back to paper searchBrowse research topicsOriginal source
Residual Astigmatism Following Toric Intraocular Lens Implantation Related to Pupil Size — Research Paper | ScholarLens