2010•18th International Conference on Nuclear Engineering: Volume 3Requires access

Measurement of Thermal Neutron Energy Spectrum and Fluence of the Thermal Column in Xi’an Pulse Reactor

Yunhong Zhong, Xinbiao Jiang, Qingyu Yu, Wenshou Zhang

Open publisher page 1 citations

Abstract

Neutron energy spectrum and fluence of the devices in a reactor are important parameters for the users. In this paper, the thermal neutron spectrum of the thermal column in Xi’an pulse reactor were measurement by the method of time of flight (TOF), and the peak of the energy spectrum is 0.0248±0.0006eV and the neutrons average energy is 0.048±0.001eV. With the spectrum results, the average cross section of 235U(n,f) and 197Au(n,γ) were calculated are respectively 92.08barn and 538.86barn. With the average cross sections, we measured the neutron fluence with the fission chamber and 197Au(n, γ) activation method. The measurements of the two methods are respectively 1.08×109n/m2s and 1.13×109n/m2s. We also calculated the standard uncertainty of the measurements: the energy spectrums’ is less than 5%, and the neutron fluence’ is less than 2.2%.

About this research paper

What this paper is about

Neutron energy spectrum and fluence of the devices in a reactor are important parameters for the users. In this paper, the thermal neutron spectrum of the thermal column in Xi’an pulse reactor were measurement by the method of time of flight (TOF), and the peak of the energy spectrum is 0.0248±0.0006eV and the neutrons average energy is 0.048±0.001eV. With the spectrum results, the average cross section of 235U(n,f) and 197Au(n,γ) were calculated are respectively 92.08barn and 538.86barn. With the average cross sections, we measured the neutron fluence with the fission chamber and 197Au(n, γ) activation method. The measurements of the two methods are respectively 1.08×109n/m2s and 1.13×109n/m2s. We also calculated the standard uncertainty of the measurements: the energy spectrums’ is less than 5%, and the neutron fluence’ is less than 2.2%.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Neutron energy spectrum and fluence of the devices in a reactor are important parameters for the users. In this paper, the thermal neutron spectrum of the thermal column in Xi’an pulse reactor were measurement by the method of time of flight (TOF), and the peak of the energy spectrum is 0.0248±0.0006eV and the neutrons average energy is 0.048±0.001eV. With the spectrum results, the average cross section of 235U(n,f) and 197Au(n,γ) were calculated are respectively 92.08barn and 538.86barn. With the average cross sections, we measured the neutron fluence with the fission chamber and 197Au(n, γ) activation method. The measurements of the two methods are respectively 1.08×109n/m2s and 1.13×109n/m2s. We also calculated the standard uncertainty of the measurements: the energy spectrums’ is less than 5%, and the neutron fluence’ is less than 2.2%.

Key concepts: Neutron flux, Neutron temperature, Fluence, Neutron, Energy spectrum, Materials science, Nuclear physics, Neutron cross section

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of Thermal Neutron Energy Spectrum and Fluence of the Thermal Column in Xi’an Pulse Reactor — Research Paper | ScholarLens