2006•Contributions to Plasma PhysicsRequires access

Comparison of Langmuir Probe and Laser Thomson Scattering Methods in the Electron Temperature Measurement in Divertor Simulator MAP‐II

A. Okamoto, S. Kado, Y. Iida, Satoru Tanaka

Open publisher page 17 citations

Abstract

Abstract In order to investigate details of anomaly in the Langmuir probe current (I)‐voltage (V) characteristics, electron temperatures and densities are measured by both Langmuir probe and laser Thomson scattering methods. The electron densities measured with both methods show good agreement in hydrogen‐molecular assisted recombination (H2‐MAR) plasmas. On the other hand, the electron temperatures measured with Langmuir probe are overestimated compared with that obtained from the Thomson scattering spectrum in the H2‐MAR plasmas. Histogram of electron current deviated from its average shows that fluctuation appeared in the electron current becomes large and the histogram distorted in temperature‐overestimated condition, especially when the probe voltage is negatively biased. (© 2006 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

About this research paper

What this paper is about

Abstract In order to investigate details of anomaly in the Langmuir probe current (I)‐voltage (V) characteristics, electron temperatures and densities are measured by both Langmuir probe and laser Thomson scattering methods. The electron densities measured with both methods show good agreement in hydrogen‐molecular assisted recombination (H2‐MAR) plasmas. On the other hand, the electron temperatures measured with Langmuir probe are overestimated compared with that obtained from the Thomson scattering spectrum in the H2‐MAR plasmas. Histogram of electron current deviated from its average shows that fluctuation appeared in the electron current becomes large and the histogram distorted in temperature‐overestimated condition, especially when the probe voltage is negatively biased. (© 2006 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract In order to investigate details of anomaly in the Langmuir probe current (I)‐voltage (V) characteristics, electron temperatures and densities are measured by both Langmuir probe and laser Thomson scattering methods. The electron densities measured with both methods show good agreement in hydrogen‐molecular assisted recombination (H2‐MAR) plasmas. On the other hand, the electron temperatures measured with Langmuir probe are overestimated compared with that obtained from the Thomson scattering spectrum in the H2‐MAR plasmas. Histogram of electron current deviated from its average shows that fluctuation appeared in the electron current becomes large and the histogram distorted in temperature‐overestimated condition, especially when the probe voltage is negatively biased. (© 2006 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Key concepts: Langmuir probe, Thomson scattering, Electron temperature, Divertor, Plasma, Plasma diagnostics, Scattering, Electron

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Langmuir Probe and Laser Thomson Scattering Methods in the Electron Temperature Measurement in Divertor Simulator MAP‐II — Research Paper | ScholarLens