2006AnaesthesiaOpen access

Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq ® and Macintosh laryngoscope

Chris Maharaj, J. F. Costello, Brendan D. Higgins, B. H. Harte, John G. Laffey

Open full text 192 citations

Abstract

Direct laryngoscopic tracheal intubation is taught to many healthcare professionals as it is a potentially lifesaving procedure. However, it is a difficult skill to acquire and maintain, and, of concern, the consequences of poorly performed intubation attempts are potentially serious. The Airtraq Laryngoscope is a novel intubation device which may possess advantages over conventional direct laryngoscopes for use by novice personnel. We conducted a prospective trial with 40 medical students who had no prior airway management experience. Following brief didactic instruction, each participant took turns in performing laryngoscopy and intubation using the Macintosh and Airtraq devices under direct supervision. Each student was allowed up to three attempts to intubate in three laryngoscopy scenarios using a Laerdal Intubation Trainer and one scenario in a Laerdal SimMan Manikin. They then performed tracheal intubation of the normal airway a second time to characterise the learning curve for each device. The Airtraq provided superior intubating conditions, resulting in greater success of intubation, particularly in the difficult laryngoscopy scenarios. In both easy and simulated difficult laryngoscopy scenarios, the Airtraq decreased the duration of intubation attempts, reduced the number of optimisation manoeuvres required, and reduced the potential for dental trauma. The Airtraq device showed a rapid learning curve and the students found it significantly easier to use. The Airtraq appears to be a superior device for novice personnel to acquire the skills of tracheal intubation.

Open-access reader

About this research paper

What this paper is about

Direct laryngoscopic tracheal intubation is taught to many healthcare professionals as it is a potentially lifesaving procedure. However, it is a difficult skill to acquire and maintain, and, of concern, the consequences of poorly performed intubation attempts are potentially serious. The Airtraq Laryngoscope is a novel intubation device which may possess advantages over conventional direct laryngoscopes for use by novice personnel. We conducted a prospective trial with 40 medical students who had no prior airway management experience. Following brief didactic instruction, each participant took turns in performing laryngoscopy and intubation using the Macintosh and Airtraq devices under direct supervision. Each student was allowed up to three attempts to intubate in three laryngoscopy scenarios using a Laerdal Intubation Trainer and one scenario in a Laerdal SimMan Manikin. They then performed tracheal intubation of the normal airway a second time to characterise the learning curve for each device. The Airtraq provided superior intubating conditions, resulting in greater success of intubation, particularly in the difficult laryngoscopy scenarios. In both easy and simulated difficult laryngoscopy scenarios, the Airtraq decreased the duration of intubation attempts, reduced the number of optimisation manoeuvres required, and reduced the potential for dental trauma. The Airtraq device showed a rapid learning curve and the students found it significantly easier to use. The Airtraq appears to be a superior device for novice personnel to acquire the skills of tracheal intubation.

Why it matters

OpenAlex reports 192 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Direct laryngoscopic tracheal intubation is taught to many healthcare professionals as it is a potentially lifesaving procedure. However, it is a difficult skill to acquire and maintain, and, of concern, the consequences of poorly performed intubation attempts are potentially serious. The Airtraq Laryngoscope is a novel intubation device which may possess advantages over conventional direct laryngoscopes for use by novice personnel. We conducted a prospective trial with 40 medical students who had no prior airway management experience. Following brief didactic instruction, each participant took turns in performing laryngoscopy and intubation using the Macintosh and Airtraq devices under direct supervision. Each student was allowed up to three attempts to intubate in three laryngoscopy scenarios using a Laerdal Intubation Trainer and one scenario in a Laerdal SimMan Manikin. They then performed tracheal intubation of the normal airway a second time to characterise the learning curve for each device. The Airtraq provided superior intubating conditions, resulting in greater success of intubation, particularly in the difficult laryngoscopy scenarios. In both easy and simulated difficult laryngoscopy scenarios, the Airtraq decreased the duration of intubation attempts, reduced the number of optimisation manoeuvres required, and reduced the potential for dental trauma. The Airtraq device showed a rapid learning curve and the students found it significantly easier to use. The Airtraq appears to be a superior device for novice personnel to acquire the skills of tracheal intubation.

Key concepts: Laryngoscopy, Intubation, Laryngoscopes, Medicine, Tracheal intubation, Airway management, Airway, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq ® and Macintosh laryngoscope — Research Paper | ScholarLens