2010Journal of GlaucomaRequires access

GDx Staging System

Paolo Brusini

Open publisher page 8 citations

Abstract

PURPOSE: To provide a reliable and easy-to-use method for classifying retinal nerve fiber layer (RNFL) damage using the parameters obtained by the scanning laser polarimeter with variable corneal compensator (GDx VCC). METHODS: GDx Staging System is a new method that uses the superior and inferior RNFL thickness values plotted on an x-y diagram to classify GDx VCC results. RNFL defects are classified into 6 stages of increasing severity and 3 classes of defect localization (superior, inferior, or diffuse defect). The diagram was created based on 320 GDx VCC tests from 84 healthy controls and from 236 patients affected by ocular hypertension or chronic open-angle glaucoma. Sensitivity and specificity of the method were assessed in a different cohort that included 161 patients with either ocular hypertension or open-angle glaucoma, and 34 normal participants. The results were correlated with both a clinical classification of the GDx VCC results and with visual field defects classified with the Glaucoma Staging System 2. RESULTS: Sensitivity and specificity of the GDx Staging System were, respectively, 88.2% and 100%. Correlations with the clinical classification and the Glaucoma Staging System 2 results were statistically significant (Spearman correlation coefficient 0.92 and 0.57, respectively; P<0.0001). CONCLUSIONS: The GDx Staging System is an easy and quick method for interpreting GDx VCC results. It can be clinically useful, especially for nonexpert ophthalmologists.

About this research paper

What this paper is about

PURPOSE: To provide a reliable and easy-to-use method for classifying retinal nerve fiber layer (RNFL) damage using the parameters obtained by the scanning laser polarimeter with variable corneal compensator (GDx VCC). METHODS: GDx Staging System is a new method that uses the superior and inferior RNFL thickness values plotted on an x-y diagram to classify GDx VCC results. RNFL defects are classified into 6 stages of increasing severity and 3 classes of defect localization (superior, inferior, or diffuse defect). The diagram was created based on 320 GDx VCC tests from 84 healthy controls and from 236 patients affected by ocular hypertension or chronic open-angle glaucoma. Sensitivity and specificity of the method were assessed in a different cohort that included 161 patients with either ocular hypertension or open-angle glaucoma, and 34 normal participants. The results were correlated with both a clinical classification of the GDx VCC results and with visual field defects classified with the Glaucoma Staging System 2. RESULTS: Sensitivity and specificity of the GDx Staging System were, respectively, 88.2% and 100%. Correlations with the clinical classification and the Glaucoma Staging System 2 results were statistically significant (Spearman correlation coefficient 0.92 and 0.57, respectively; P<0.0001). CONCLUSIONS: The GDx Staging System is an easy and quick method for interpreting GDx VCC results. It can be clinically useful, especially for nonexpert ophthalmologists.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To provide a reliable and easy-to-use method for classifying retinal nerve fiber layer (RNFL) damage using the parameters obtained by the scanning laser polarimeter with variable corneal compensator (GDx VCC). METHODS: GDx Staging System is a new method that uses the superior and inferior RNFL thickness values plotted on an x-y diagram to classify GDx VCC results. RNFL defects are classified into 6 stages of increasing severity and 3 classes of defect localization (superior, inferior, or diffuse defect). The diagram was created based on 320 GDx VCC tests from 84 healthy controls and from 236 patients affected by ocular hypertension or chronic open-angle glaucoma. Sensitivity and specificity of the method were assessed in a different cohort that included 161 patients with either ocular hypertension or open-angle glaucoma, and 34 normal participants. The results were correlated with both a clinical classification of the GDx VCC results and with visual field defects classified with the Glaucoma Staging System 2. RESULTS: Sensitivity and specificity of the GDx Staging System were, respectively, 88.2% and 100%. Correlations with the clinical classification and the Glaucoma Staging System 2 results were statistically significant (Spearman correlation coefficient 0.92 and 0.57, respectively; P<0.0001). CONCLUSIONS: The GDx Staging System is an easy and quick method for interpreting GDx VCC results. It can be clinically useful, especially for nonexpert ophthalmologists.

Key concepts: Medicine, Scanning laser polarimetry, Glaucoma, Ophthalmology, Open angle glaucoma, Nerve fiber layer, Retinal, Staging system

Related papers

Back to paper searchBrowse research topicsOriginal source
GDx Staging System — Research Paper | ScholarLens