1994•Pacing and Clinical ElectrophysiologyRequires access

A Pilot Study: Defibrillation Thresholds in Dogs are Similar with Isoflurane, Halothane, and Pentobarbital

ALISON S. JARVIS, STUART P. LAHTINEN

Open publisher page 10 citations

Abstract

The objective of this pilot study was to determine if three common anesthetic drugs have differing effects on the measurement of defibrillation thresholds (DFT) in dogs. The drugs compared were pentobarbital, isoflurane, and halothane. We used six dogs, which were surgically instrumented, in a chronic study design. Each dog had two internal defibrillation patches placed on its heart, which were used to deliver the defibrillation energy. DFT was determined while each dog was anesthetized under each of the listed drugs in a crossover design. This pilot study suggests that differences in DFT due to the anesthetic drugs is not significant in studies with low numbers of animals (halothane 14.5 +/- 1.0, isoflurane 14.2 +/- 1.0, pentobarbital 12.8 +/- 1.0; P = NS; mean +/- SE). The variation in DFT between individual animals is much larger than the difference in DFT due to the drugs.

About this research paper

What this paper is about

The objective of this pilot study was to determine if three common anesthetic drugs have differing effects on the measurement of defibrillation thresholds (DFT) in dogs. The drugs compared were pentobarbital, isoflurane, and halothane. We used six dogs, which were surgically instrumented, in a chronic study design. Each dog had two internal defibrillation patches placed on its heart, which were used to deliver the defibrillation energy. DFT was determined while each dog was anesthetized under each of the listed drugs in a crossover design. This pilot study suggests that differences in DFT due to the anesthetic drugs is not significant in studies with low numbers of animals (halothane 14.5 +/- 1.0, isoflurane 14.2 +/- 1.0, pentobarbital 12.8 +/- 1.0; P = NS; mean +/- SE). The variation in DFT between individual animals is much larger than the difference in DFT due to the drugs.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The objective of this pilot study was to determine if three common anesthetic drugs have differing effects on the measurement of defibrillation thresholds (DFT) in dogs. The drugs compared were pentobarbital, isoflurane, and halothane. We used six dogs, which were surgically instrumented, in a chronic study design. Each dog had two internal defibrillation patches placed on its heart, which were used to deliver the defibrillation energy. DFT was determined while each dog was anesthetized under each of the listed drugs in a crossover design. This pilot study suggests that differences in DFT due to the anesthetic drugs is not significant in studies with low numbers of animals (halothane 14.5 +/- 1.0, isoflurane 14.2 +/- 1.0, pentobarbital 12.8 +/- 1.0; P = NS; mean +/- SE). The variation in DFT between individual animals is much larger than the difference in DFT due to the drugs.

Key concepts: Pentobarbital, Halothane, Medicine, Isoflurane, Defibrillation threshold, Defibrillation, Anesthetic, Anesthesia