2006Journal of Neurosurgery PediatricsRequires access

Collagen nerve guides for surgical repair of brachial plexus birth injury

William W. Ashley, Trisha Weatherly, Tae Sung Park

Open publisher page 92 citations

Abstract

OBJECT: Standard brachial plexus repair techniques often involve autologous nerve graft placement and neurotization. However, when performed to treat severe injuries, this procedure can sometimes yield poor results. Moreover, harvesting the autologous graft is time-consuming and exposes the patient to additional surgical risks. To improve surgical outcomes and reduce surgical risks associated with autologous nerve graft retrieval and placement, the authors use collagen matrix tubes (Neurogen) instead of autologous nerve graft material. METHODS: Between 1991 and 2005, the authors surgically treated 65 infants who had suffered brachial plexus injury at birth. During this time, seven patients were treated using collagen matrix tubes (Neurogen). This study is a retrospective analysis of the initial five patients who were treated using the tubes. Two patients underwent tube placement recently and were excluded from the analysis because of the inadequate follow-up period. Four of the five patients experienced a good recovery (motor scale composite [MSC] > 0.6), and three exhibited an excellent recovery (MSC > 0.75) at 2 years postoperatively. The MSC improved by an average of 69 and 78% at 1 and 2 years, respectively. The movement scores improved to greater than or equal to 50% range of motion in most patients, and the contractures were usually mild or moderate. Follow-up physical and occupational therapy evaluations confirm these patients' functional status. When last seen, four of five of these children could feed and dress themselves. CONCLUSIONS: Technically, the use of the collagen matrix tubes was straightforward and efficient, and there were no complications. The outcomes in this small series are encouraging.

About this research paper

What this paper is about

OBJECT: Standard brachial plexus repair techniques often involve autologous nerve graft placement and neurotization. However, when performed to treat severe injuries, this procedure can sometimes yield poor results. Moreover, harvesting the autologous graft is time-consuming and exposes the patient to additional surgical risks. To improve surgical outcomes and reduce surgical risks associated with autologous nerve graft retrieval and placement, the authors use collagen matrix tubes (Neurogen) instead of autologous nerve graft material. METHODS: Between 1991 and 2005, the authors surgically treated 65 infants who had suffered brachial plexus injury at birth. During this time, seven patients were treated using collagen matrix tubes (Neurogen). This study is a retrospective analysis of the initial five patients who were treated using the tubes. Two patients underwent tube placement recently and were excluded from the analysis because of the inadequate follow-up period. Four of the five patients experienced a good recovery (motor scale composite [MSC] > 0.6), and three exhibited an excellent recovery (MSC > 0.75) at 2 years postoperatively. The MSC improved by an average of 69 and 78% at 1 and 2 years, respectively. The movement scores improved to greater than or equal to 50% range of motion in most patients, and the contractures were usually mild or moderate. Follow-up physical and occupational therapy evaluations confirm these patients' functional status. When last seen, four of five of these children could feed and dress themselves. CONCLUSIONS: Technically, the use of the collagen matrix tubes was straightforward and efficient, and there were no complications. The outcomes in this small series are encouraging.

Why it matters

OpenAlex reports 92 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECT: Standard brachial plexus repair techniques often involve autologous nerve graft placement and neurotization. However, when performed to treat severe injuries, this procedure can sometimes yield poor results. Moreover, harvesting the autologous graft is time-consuming and exposes the patient to additional surgical risks. To improve surgical outcomes and reduce surgical risks associated with autologous nerve graft retrieval and placement, the authors use collagen matrix tubes (Neurogen) instead of autologous nerve graft material. METHODS: Between 1991 and 2005, the authors surgically treated 65 infants who had suffered brachial plexus injury at birth. During this time, seven patients were treated using collagen matrix tubes (Neurogen). This study is a retrospective analysis of the initial five patients who were treated using the tubes. Two patients underwent tube placement recently and were excluded from the analysis because of the inadequate follow-up period. Four of the five patients experienced a good recovery (motor scale composite [MSC] > 0.6), and three exhibited an excellent recovery (MSC > 0.75) at 2 years postoperatively. The MSC improved by an average of 69 and 78% at 1 and 2 years, respectively. The movement scores improved to greater than or equal to 50% range of motion in most patients, and the contractures were usually mild or moderate. Follow-up physical and occupational therapy evaluations confirm these patients' functional status. When last seen, four of five of these children could feed and dress themselves. CONCLUSIONS: Technically, the use of the collagen matrix tubes was straightforward and efficient, and there were no complications. The outcomes in this small series are encouraging.

Key concepts: Medicine, Brachial plexus, Surgery, Muscle contracture, Brachial plexus injury, Nerve repair, Retrospective cohort study, Nerve injury