1982IEEE Transactions on Nuclear ScienceRequires access

An Array of 12 Planar Germanium Detectors for in Situ Gamma Spectroscopy

Joseph F. Kordas, D. L. Sawyer, John A. Kirby, J.H. Ewins

Open publisher page 1 citations

Abstract

There is a continuing need at the Nevada Test Site (NTS) for sensitive instruments that quantify surface concentrations of radionuclides. We have designed, fabricated, and field tested an array of 12 high-purity germanium planar detectors in a single cryostat. The detector system has a total surface area of 120 cm2 and internal shielding. The detectors are 0.8-cm thick and are individually encapsulated. This system was primarily designed for in situ detection of plutonium via the 241Am 60-keV gamma ray; however, it will also be used for in vivo lung counting and sample counting. We have fielded it at the NTS and found it to have a minimum detectable activity (MDA) for 241Am of about a factor of four lower than that of our four-detector system.

About this research paper

What this paper is about

There is a continuing need at the Nevada Test Site (NTS) for sensitive instruments that quantify surface concentrations of radionuclides. We have designed, fabricated, and field tested an array of 12 high-purity germanium planar detectors in a single cryostat. The detector system has a total surface area of 120 cm2 and internal shielding. The detectors are 0.8-cm thick and are individually encapsulated. This system was primarily designed for in situ detection of plutonium via the 241Am 60-keV gamma ray; however, it will also be used for in vivo lung counting and sample counting. We have fielded it at the NTS and found it to have a minimum detectable activity (MDA) for 241Am of about a factor of four lower than that of our four-detector system.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

There is a continuing need at the Nevada Test Site (NTS) for sensitive instruments that quantify surface concentrations of radionuclides. We have designed, fabricated, and field tested an array of 12 high-purity germanium planar detectors in a single cryostat. The detector system has a total surface area of 120 cm2 and internal shielding. The detectors are 0.8-cm thick and are individually encapsulated. This system was primarily designed for in situ detection of plutonium via the 241Am 60-keV gamma ray; however, it will also be used for in vivo lung counting and sample counting. We have fielded it at the NTS and found it to have a minimum detectable activity (MDA) for 241Am of about a factor of four lower than that of our four-detector system.

Key concepts: Semiconductor detector, Germanium, Detector, Cryostat, Electromagnetic shielding, Planar, Gamma spectroscopy, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
An Array of 12 Planar Germanium Detectors for in Situ Gamma Spectroscopy — Research Paper | ScholarLens