A Comparison of Changes in Cardiac Preload Variables During Graded Hypovolemia and Hypervolemia in Mechanically Ventilated Dogs
Yoshihisa Fujita, Tokunori Yamamoto, Itsuro Sano, Naoki Yoshioka, Hajime Hinenoya
Abstract
Yoshihisa Fujita, Tokunori Yamamoto, Itsuro Sano, Naoki Yoshioka, Hajime Hinenoya
Abstract
In Brief We developed an online monitoring system to measure systolic blood pressure variation (SPV) and its down (dDown) and up components, along with pulse pressure variation (dPP). Using the system, we compared different cardiac preload indicators—such as stroke volume variation (SVV) and corrected flow time (FTc)—along with central venous pressure and pulmonary artery occlusion pressure in mechanically-ventilated dogs during normovolemia, graded hypovolemia (−200 and −350 mL), and hypervolemia (+200 and +350 mL). We simultaneously measured these preload indicators along with global hemodynamic variables and investigated their validity and limitations to access preload changes. SPV increased from 4.8 ± 1.4 mm Hg at baseline to 11.2 ± 1.8 mm Hg during hypovolemia (−350 mL), but it did not change significantly during hypervolemia. Similar changes were observed with dDown, dPP, and SVV. FTc, conversely, increased during hypervolemia but remained unchanged during hypovolemia. The results of this study indicate that SPV, dDown, dPP, and SVV are useful indicators of hypovolemia, but not of hypervolemia. Conversely, hypovolemia could not be detected reliably by FTc, but it does reflect blood volume changes during hypervolemia. Although SPV, dDown, and dPP measurements require no additional invasion and cost beyond arterial cannulation, their limits must be kept in mind for the monitoring of blood volume status in mechanically-ventilated patients. IMPLICATIONS: We simultaneously monitored dynamic preload variables—such as systolic blood pressure variation, its down component, pulse pressure variation, stroke volume variation, and esophageal Doppler-derived corrected flow time—during induced hypovolemia and hypervolemia. The results demonstrated that these variables, with the exception of corrected flow time, are useful indicators of hypovolemia, but not of hypervolemia.
OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In Brief We developed an online monitoring system to measure systolic blood pressure variation (SPV) and its down (dDown) and up components, along with pulse pressure variation (dPP). Using the system, we compared different cardiac preload indicators—such as stroke volume variation (SVV) and corrected flow time (FTc)—along with central venous pressure and pulmonary artery occlusion pressure in mechanically-ventilated dogs during normovolemia, graded hypovolemia (−200 and −350 mL), and hypervolemia (+200 and +350 mL). We simultaneously measured these preload indicators along with global hemodynamic variables and investigated their validity and limitations to access preload changes. SPV increased from 4.8 ± 1.4 mm Hg at baseline to 11.2 ± 1.8 mm Hg during hypovolemia (−350 mL), but it did not change significantly during hypervolemia. Similar changes were observed with dDown, dPP, and SVV. FTc, conversely, increased during hypervolemia but remained unchanged during hypovolemia. The results of this study indicate that SPV, dDown, dPP, and SVV are useful indicators of hypovolemia, but not of hypervolemia. Conversely, hypovolemia could not be detected reliably by FTc, but it does reflect blood volume changes during hypervolemia. Although SPV, dDown, and dPP measurements require no additional invasion and cost beyond arterial cannulation, their limits must be kept in mind for the monitoring of blood volume status in mechanically-ventilated patients. IMPLICATIONS: We simultaneously monitored dynamic preload variables—such as systolic blood pressure variation, its down component, pulse pressure variation, stroke volume variation, and esophageal Doppler-derived corrected flow time—during induced hypovolemia and hypervolemia. The results demonstrated that these variables, with the exception of corrected flow time, are useful indicators of hypovolemia, but not of hypervolemia.
Key concepts: Hypervolemia, Hypovolemia, Preload, Cardiology, Medicine, Internal medicine, Hemodynamics, Blood volume