1999Analytical ChemistryRequires access

Subzero-Temperature Liquid−Liquid Extraction of Benzodiazepines for High-Performance Liquid Chromatography

Manabu Yoshida, Atsushi Akane

Open publisher page 61 citations

Abstract

On the basis of the phenomenon that hydrophilic acetonitrile is separated from the aqueous phase at -20 degrees C, we employed a novel extraction method, "subzero-temperature liquid-liquid extraction", to extract benzodiazepines (estazolam and triazolam) from serum or aqueous solution for liquid chromatography. A 1:1 mixture of acetonitrile and the specimen was cooled at -20 degrees C for 20 min to separate the acetonitrile and aqueous phases. The acetonitrile phase was directly injected into a high-performance liquid chromatograph. Recovery rates of the drugs following the first subzero-temperature liquid-liquid extraction were 50.3 +/- 0.6-54.0 +/- 0.9%, which were lower than those (73.9 +/- 3.3-80.6 +/- 0.6% and 81.6 +/- 4.7-96.1 +/- 2.6%) of the first conventional liquid-liquid extraction using diethyl ether and solid-phase extraction using a Sep-Pak C18 column, respectively. However, three to four repeated subzero-temperature liquid-liquid extractions and conventional liquid-liquid extractions resulted in recovery of almost 100% of the drugs. In the chromatogram of the benzodiazepines recovered from serum by the subzero-temperature extraction, no coextracted component interfered with determination of the drugs. Detection limits of the drugs were 0.02-0.08 microgram/mL, and coefficients of variance were 1.14-2.17% suggesting high reproducibility.

About this research paper

What this paper is about

On the basis of the phenomenon that hydrophilic acetonitrile is separated from the aqueous phase at -20 degrees C, we employed a novel extraction method, "subzero-temperature liquid-liquid extraction", to extract benzodiazepines (estazolam and triazolam) from serum or aqueous solution for liquid chromatography. A 1:1 mixture of acetonitrile and the specimen was cooled at -20 degrees C for 20 min to separate the acetonitrile and aqueous phases. The acetonitrile phase was directly injected into a high-performance liquid chromatograph. Recovery rates of the drugs following the first subzero-temperature liquid-liquid extraction were 50.3 +/- 0.6-54.0 +/- 0.9%, which were lower than those (73.9 +/- 3.3-80.6 +/- 0.6% and 81.6 +/- 4.7-96.1 +/- 2.6%) of the first conventional liquid-liquid extraction using diethyl ether and solid-phase extraction using a Sep-Pak C18 column, respectively. However, three to four repeated subzero-temperature liquid-liquid extractions and conventional liquid-liquid extractions resulted in recovery of almost 100% of the drugs. In the chromatogram of the benzodiazepines recovered from serum by the subzero-temperature extraction, no coextracted component interfered with determination of the drugs. Detection limits of the drugs were 0.02-0.08 microgram/mL, and coefficients of variance were 1.14-2.17% suggesting high reproducibility.

Why it matters

OpenAlex reports 61 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

On the basis of the phenomenon that hydrophilic acetonitrile is separated from the aqueous phase at -20 degrees C, we employed a novel extraction method, "subzero-temperature liquid-liquid extraction", to extract benzodiazepines (estazolam and triazolam) from serum or aqueous solution for liquid chromatography. A 1:1 mixture of acetonitrile and the specimen was cooled at -20 degrees C for 20 min to separate the acetonitrile and aqueous phases. The acetonitrile phase was directly injected into a high-performance liquid chromatograph. Recovery rates of the drugs following the first subzero-temperature liquid-liquid extraction were 50.3 +/- 0.6-54.0 +/- 0.9%, which were lower than those (73.9 +/- 3.3-80.6 +/- 0.6% and 81.6 +/- 4.7-96.1 +/- 2.6%) of the first conventional liquid-liquid extraction using diethyl ether and solid-phase extraction using a Sep-Pak C18 column, respectively. However, three to four repeated subzero-temperature liquid-liquid extractions and conventional liquid-liquid extractions resulted in recovery of almost 100% of the drugs. In the chromatogram of the benzodiazepines recovered from serum by the subzero-temperature extraction, no coextracted component interfered with determination of the drugs. Detection limits of the drugs were 0.02-0.08 microgram/mL, and coefficients of variance were 1.14-2.17% suggesting high reproducibility.

Key concepts: Chemistry, Chromatography, Extraction (chemistry), Liquid liquid, Liquid–liquid extraction, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Subzero-Temperature Liquid−Liquid Extraction of Benzodiazepines for High-Performance Liquid Chromatography — Research Paper | ScholarLens