2006•Chemical Engineering & TechnologyRequires access

Effects of Liquid Holdup in Condensers on the Start-Up of Reactive Distillation Columns

Huaqiang Wu, Ziheng Tang, H.-B. Gao, H. Hu, Xinchun Lu, S.-Y. Li

Open publisher page 5 citations

Abstract

Compared with start-ups in conventional distillation columns, those in reactive distillation (RD) columns are much more time and energy consuming, and generate a large amount of by-products which are not easy to deal with together. For several years, researchers have been trying out different methods to shorten the time required to lower the cost of the start-up. In this work, a rigorous dynamic model in the ChemCAD simulator is applied to model the start-up process for the esterification of ethyl acetate in a reactive distillation column. In the model, two sets of equations are employed: one for the fill-up and heating stage and the other for the equilibration process which follows. In the fill-up and heating stage, fluctuation curves of the reboiler temperatures with respect to time which are similar to those for conventional distillation columns are observed, while in the equilibration process it is found that the increase of the liquid holdup volume in the condenser reduces the time required to reach steady state for the reactive column and decreases the liquid holdup volume in the reboiler at the equilibrium state. This shows that the liquid holdup volume in the condenser has an important effect on the start-up of reactive distillation columns.

About this research paper

What this paper is about

Compared with start-ups in conventional distillation columns, those in reactive distillation (RD) columns are much more time and energy consuming, and generate a large amount of by-products which are not easy to deal with together. For several years, researchers have been trying out different methods to shorten the time required to lower the cost of the start-up. In this work, a rigorous dynamic model in the ChemCAD simulator is applied to model the start-up process for the esterification of ethyl acetate in a reactive distillation column. In the model, two sets of equations are employed: one for the fill-up and heating stage and the other for the equilibration process which follows. In the fill-up and heating stage, fluctuation curves of the reboiler temperatures with respect to time which are similar to those for conventional distillation columns are observed, while in the equilibration process it is found that the increase of the liquid holdup volume in the condenser reduces the time required to reach steady state for the reactive column and decreases the liquid holdup volume in the reboiler at the equilibrium state. This shows that the liquid holdup volume in the condenser has an important effect on the start-up of reactive distillation columns.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Compared with start-ups in conventional distillation columns, those in reactive distillation (RD) columns are much more time and energy consuming, and generate a large amount of by-products which are not easy to deal with together. For several years, researchers have been trying out different methods to shorten the time required to lower the cost of the start-up. In this work, a rigorous dynamic model in the ChemCAD simulator is applied to model the start-up process for the esterification of ethyl acetate in a reactive distillation column. In the model, two sets of equations are employed: one for the fill-up and heating stage and the other for the equilibration process which follows. In the fill-up and heating stage, fluctuation curves of the reboiler temperatures with respect to time which are similar to those for conventional distillation columns are observed, while in the equilibration process it is found that the increase of the liquid holdup volume in the condenser reduces the time required to reach steady state for the reactive column and decreases the liquid holdup volume in the reboiler at the equilibrium state. This shows that the liquid holdup volume in the condenser has an important effect on the start-up of reactive distillation columns.

Key concepts: Reboiler, Reactive distillation, Condenser (optics), Distillation, Volume (thermodynamics), Chemistry, Process (computing), Work (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of Liquid Holdup in Condensers on the Start-Up of Reactive Distillation Columns — Research Paper | ScholarLens