2011Unpublished venueRequires access

Electrical analog model of arterial compliance during reactive hyperemia

Layli S. Goldoozian, Edmond Zahedi

Open publisher page 4 citations

Abstract

Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmogram (PPG) changes during reactive hyperemia. It was shown that the amplitude of the PPG pulse (FMD-PPG) changed in a quite similar manner to that of the artery diameter in the method of the FMD-US i.e. increases following releasing the cuff and then gradually returns to baseline. In this study PPG changes following reactive hyperaemia were modelled using time-varying passive electrical elements (R, L and C). The output of the electric analog model matched relatively well (fitness of 82.47%) the PPG-AC signal.

About this research paper

What this paper is about

Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmogram (PPG) changes during reactive hyperemia. It was shown that the amplitude of the PPG pulse (FMD-PPG) changed in a quite similar manner to that of the artery diameter in the method of the FMD-US i.e. increases following releasing the cuff and then gradually returns to baseline. In this study PPG changes following reactive hyperaemia were modelled using time-varying passive electrical elements (R, L and C). The output of the electric analog model matched relatively well (fitness of 82.47%) the PPG-AC signal.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmogram (PPG) changes during reactive hyperemia. It was shown that the amplitude of the PPG pulse (FMD-PPG) changed in a quite similar manner to that of the artery diameter in the method of the FMD-US i.e. increases following releasing the cuff and then gradually returns to baseline. In this study PPG changes following reactive hyperaemia were modelled using time-varying passive electrical elements (R, L and C). The output of the electric analog model matched relatively well (fitness of 82.47%) the PPG-AC signal.

Key concepts: Hyperaemia, Reactive hyperemia, Photoplethysmogram, Cuff, Biomedical engineering, Cardiology, Medicine, Compliance (psychology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Electrical analog model of arterial compliance during reactive hyperemia — Research Paper | ScholarLens