1983•Eisei kagakuOpen access

Atomic absorption spectrophotometric determination of polyoxyethylene-type nonionic surfactants in water.

Atsuko Adachi, Tadashi Kobayashi

Open full text 1 citations

Abstract

A simple, precise and sensitive method for the determination of polyoxyethylene-type nonionic surfactants in water was established by using atomic absorption spectrophotometry with a graphite furnace atomizer. The proposed method is based on the atomic absorption spectrophotometric determination of cobalt in a chelate complex produced by the reaction of nonionic surfactants with ammonium cobaltothiocyanate reagent used in the spectrophotometric method of JIS K 3364 and K 0102. The interference by anionic and cationic surfactants could be removed by a cleanup procedure involving ion exchange resin column chromatography. The recoveries of polyoxyethylene-n-dodecyl ether as a standard compound in various environmental water samples were within the range of 93.0-111.3% and the coefficients of variation were within 9.0% ; these values are satisfactory. The proposed method does not require any preliminary concentration procedure because of the high sensitivity (detection limit : 0.001 mg/l). There was a highly significant correlation (γ=0.999) between the results obtained by the proposed method and those of the JIS K 3364 and K 0102 spectrophotometric method. The assayed values of nonionic surfactants in water samples obtained from 18 rivers were distributed between 0.001 and 0.895 mg/l.

Open-access reader

About this research paper

What this paper is about

A simple, precise and sensitive method for the determination of polyoxyethylene-type nonionic surfactants in water was established by using atomic absorption spectrophotometry with a graphite furnace atomizer. The proposed method is based on the atomic absorption spectrophotometric determination of cobalt in a chelate complex produced by the reaction of nonionic surfactants with ammonium cobaltothiocyanate reagent used in the spectrophotometric method of JIS K 3364 and K 0102. The interference by anionic and cationic surfactants could be removed by a cleanup procedure involving ion exchange resin column chromatography. The recoveries of polyoxyethylene-n-dodecyl ether as a standard compound in various environmental water samples were within the range of 93.0-111.3% and the coefficients of variation were within 9.0% ; these values are satisfactory. The proposed method does not require any preliminary concentration procedure because of the high sensitivity (detection limit : 0.001 mg/l). There was a highly significant correlation (γ=0.999) between the results obtained by the proposed method and those of the JIS K 3364 and K 0102 spectrophotometric method. The assayed values of nonionic surfactants in water samples obtained from 18 rivers were distributed between 0.001 and 0.895 mg/l.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, precise and sensitive method for the determination of polyoxyethylene-type nonionic surfactants in water was established by using atomic absorption spectrophotometry with a graphite furnace atomizer. The proposed method is based on the atomic absorption spectrophotometric determination of cobalt in a chelate complex produced by the reaction of nonionic surfactants with ammonium cobaltothiocyanate reagent used in the spectrophotometric method of JIS K 3364 and K 0102. The interference by anionic and cationic surfactants could be removed by a cleanup procedure involving ion exchange resin column chromatography. The recoveries of polyoxyethylene-n-dodecyl ether as a standard compound in various environmental water samples were within the range of 93.0-111.3% and the coefficients of variation were within 9.0% ; these values are satisfactory. The proposed method does not require any preliminary concentration procedure because of the high sensitivity (detection limit : 0.001 mg/l). There was a highly significant correlation (γ=0.999) between the results obtained by the proposed method and those of the JIS K 3364 and K 0102 spectrophotometric method. The assayed values of nonionic surfactants in water samples obtained from 18 rivers were distributed between 0.001 and 0.895 mg/l.

Key concepts: Chemistry, Reagent, Atomic absorption spectroscopy, Spectrophotometry, Detection limit, Cationic polymerization, Ether, Absorption (acoustics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Atomic absorption spectrophotometric determination of polyoxyethylene-type nonionic surfactants in water. — Research Paper | ScholarLens