COMPARATIVE STUDY OF FORCED DEGRADATION BEHAVIOR OF PRASUGREL BY UPLC AND HPLC AND THE DEVELOPMENT OF VALIDATED STABILITY INDICATING ASSAY METHOD
Kapendra Sahu, Chandrabose Karthikeyan, N. S. Hari Narayana Moorthy, Piyush Trivedi
Abstract
Kapendra Sahu, Chandrabose Karthikeyan, N. S. Hari Narayana Moorthy, Piyush Trivedi
Abstract
A novel stability-indicating ultra-performance liquid chromatographic (UPLC) assay method was developed and validated for prasugrel and its degradation products. The UPLC separation was performed on Acquity® UPLC BEH C18 column (1.7 µm, 2.1 mm × 150 mm) using isocratic mode (acetonitrile:water, 80:20 v/v) at flow rate of 0.1 mL/min and the high performance liquid chromatography (HPLC) separation was achieved on Phenomenex® C8 column using isocratic mode (acetonitrile:10 mM ammonium acetate, 85:15 v/v) at flow rate of 0.9 mL/min. Prasugrel was found to degrade significantly in hydrolytic (acid, alkali, and neutral), and oxidative stress conditions and was stable in thermal and photolytic stress conditions. The RSD (%) values calculated for the AUC of UPLC and HPLC are 0.0039 and 0.0015, respectively. The UPLC and HPLC linearity of the proposed method were investigated in the range of 10–60 µg/mL. The r2 value of UPLC and HPLC were found to be 0.9980 and 0.9983, respectively. Method detection limit (MDL) and method quantification limit (MQL) were found to be 0.20 µg/mL and 1.00 µg/mL for UPLC and 0.50 µg/mL and 1.80 µg/mL for HPLC, respectively. The RSD (%) values for intra-day and inter-day precision were <1.0%, confirming that the method is sufficiently precise. The validation studies were carried out fulfilling ICH requirements.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel stability-indicating ultra-performance liquid chromatographic (UPLC) assay method was developed and validated for prasugrel and its degradation products. The UPLC separation was performed on Acquity® UPLC BEH C18 column (1.7 µm, 2.1 mm × 150 mm) using isocratic mode (acetonitrile:water, 80:20 v/v) at flow rate of 0.1 mL/min and the high performance liquid chromatography (HPLC) separation was achieved on Phenomenex® C8 column using isocratic mode (acetonitrile:10 mM ammonium acetate, 85:15 v/v) at flow rate of 0.9 mL/min. Prasugrel was found to degrade significantly in hydrolytic (acid, alkali, and neutral), and oxidative stress conditions and was stable in thermal and photolytic stress conditions. The RSD (%) values calculated for the AUC of UPLC and HPLC are 0.0039 and 0.0015, respectively. The UPLC and HPLC linearity of the proposed method were investigated in the range of 10–60 µg/mL. The r2 value of UPLC and HPLC were found to be 0.9980 and 0.9983, respectively. Method detection limit (MDL) and method quantification limit (MQL) were found to be 0.20 µg/mL and 1.00 µg/mL for UPLC and 0.50 µg/mL and 1.80 µg/mL for HPLC, respectively. The RSD (%) values for intra-day and inter-day precision were <1.0%, confirming that the method is sufficiently precise. The validation studies were carried out fulfilling ICH requirements.
Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Ammonium acetate, Acetonitrile, Detection limit