2008Journal of ParasitologyRequires access

A Cautionary Note on the Use of Nested PCR for Parasite Screening—An Example From Avian Blood Parasites

Eszter Szöllősi, Olof Hellgren, Dennis Hasselquist

Open publisher page 30 citations

Abstract

The use of new powerful nested polymerase chain reaction (PCR) techniques to identify and screen for prevalence of parasites has a huge potential. It allows for the detection and identification of low-intensity infections, but its high sensitivity and technical setup may also induce problems. Here, we report a cautionary note regarding misleading amplification of avian malaria species (Haemoproteus and Plasmodium) during Leucocytozoon spp. detection. We used a previously described nested PCR method for the molecular detection of avian malaria and Leucocytozoon spp. In the first step of the PCR protocol, these parasites are detected simultaneously; in the second PCR, Haemoproteus and Plasmodium spp. are separated from Leucocytozoon spp. However, in certain cases when a bird was infected with avian malaria, we obtained a slightly longer PCR product during the detection of Leucocytozoon spp. Our data imply that these "false" Leucocytozoon fragments are the consequences of strong amplification of certain malaria lineages in the first PCR, which can also be detected after the second PCR amplification that is specific to Leucocytozoon spp. parasites. Because these "false" Leucocytozoon fragments are slightly longer than the normal Leucocytozoon fragments, we suggest the use of well-separating agarose gels, several positive controls, and molecular standards to facilitate their separation. If one obtains a fragment that differs in length from the one expected for Leucocytozoon spp., sequencing is essential. More generally, in order to limit this type of problem with nested PCR protocols, we suggest that the first and the second primer pair be chosen so that they have different annealing temperatures.

About this research paper

What this paper is about

The use of new powerful nested polymerase chain reaction (PCR) techniques to identify and screen for prevalence of parasites has a huge potential. It allows for the detection and identification of low-intensity infections, but its high sensitivity and technical setup may also induce problems. Here, we report a cautionary note regarding misleading amplification of avian malaria species (Haemoproteus and Plasmodium) during Leucocytozoon spp. detection. We used a previously described nested PCR method for the molecular detection of avian malaria and Leucocytozoon spp. In the first step of the PCR protocol, these parasites are detected simultaneously; in the second PCR, Haemoproteus and Plasmodium spp. are separated from Leucocytozoon spp. However, in certain cases when a bird was infected with avian malaria, we obtained a slightly longer PCR product during the detection of Leucocytozoon spp. Our data imply that these "false" Leucocytozoon fragments are the consequences of strong amplification of certain malaria lineages in the first PCR, which can also be detected after the second PCR amplification that is specific to Leucocytozoon spp. parasites. Because these "false" Leucocytozoon fragments are slightly longer than the normal Leucocytozoon fragments, we suggest the use of well-separating agarose gels, several positive controls, and molecular standards to facilitate their separation. If one obtains a fragment that differs in length from the one expected for Leucocytozoon spp., sequencing is essential. More generally, in order to limit this type of problem with nested PCR protocols, we suggest that the first and the second primer pair be chosen so that they have different annealing temperatures.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The use of new powerful nested polymerase chain reaction (PCR) techniques to identify and screen for prevalence of parasites has a huge potential. It allows for the detection and identification of low-intensity infections, but its high sensitivity and technical setup may also induce problems. Here, we report a cautionary note regarding misleading amplification of avian malaria species (Haemoproteus and Plasmodium) during Leucocytozoon spp. detection. We used a previously described nested PCR method for the molecular detection of avian malaria and Leucocytozoon spp. In the first step of the PCR protocol, these parasites are detected simultaneously; in the second PCR, Haemoproteus and Plasmodium spp. are separated from Leucocytozoon spp. However, in certain cases when a bird was infected with avian malaria, we obtained a slightly longer PCR product during the detection of Leucocytozoon spp. Our data imply that these "false" Leucocytozoon fragments are the consequences of strong amplification of certain malaria lineages in the first PCR, which can also be detected after the second PCR amplification that is specific to Leucocytozoon spp. parasites. Because these "false" Leucocytozoon fragments are slightly longer than the normal Leucocytozoon fragments, we suggest the use of well-separating agarose gels, several positive controls, and molecular standards to facilitate their separation. If one obtains a fragment that differs in length from the one expected for Leucocytozoon spp., sequencing is essential. More generally, in order to limit this type of problem with nested PCR protocols, we suggest that the first and the second primer pair be chosen so that they have different annealing temperatures.

Key concepts: Leucocytozoon, Haemoproteus, Biology, Plasmodium (life cycle), Nested polymerase chain reaction, Avian malaria, Virology, Polymerase chain reaction

Related papers

Back to paper searchBrowse research topicsOriginal source
A Cautionary Note on the Use of Nested PCR for Parasite Screening—An Example From Avian Blood Parasites — Research Paper | ScholarLens