2011•Archivum Immunologiae et Therapiae ExperimentalisRequires access

Serodiagnosis of Borreliosis: Indirect Immunofluorescence Assay, Enzyme-Linked Immunosorbent Assay and Immunoblotting

Iwona Wojciechowska‐Koszko, Iwona Mączyńska, Zbigniew Szych, Stefania Giedrys‐Kalemba

Open publisher page 12 citations

Abstract

Lyme disease is an infectious, multi-system, tick-borne disease caused by genospecies of Borrelia burgdorferi bacteria sensu lato, characterized by remarkable heterogeneity. In this situation choosing an optimal antigen array for diagnostic tests seems problematic. The serological tests for borrelia routinely done in laboratories often produce ambiguous results, which makes a proper diagnosis rather complicated and thus delays the implementation of an appropriate treatment regimen. Thirty-seven outpatients and eight inpatients with suspected borreliosis diagnosis hospitalized at the Clinics of the Pomeranian Medical University (Szczecin, Poland), participated in the study. In order to detect the antibodies against Borrelia sensu lato three kinds of serological tests were used: indirect immunofluorescence assay (IIFA), enzyme-linked immunosorbent assay (ELISA), and immunoblot. The IIFA and immunoblot tests conducted on 45 patients (100%) produced positive results for both the IgM and IgG antibody types. In the case of ELISA, positive or borderline results were observed in only 24 patients (53.3%). The immunoblot test for IgM most frequently detected antibodies against the outer surface protein C (OspC) antigen (p25), and, in the case of IgG, against the recombinant variable surface antigen (VlsE). The IIFA screening test used for diagnosing Lyme borreliosis produced the highest percentage of positive results, which were then confirmed by immunoblot, but not by ELISA. Therefore using only ELISA as a screening test or for diagnosing Lyme borreliosis seems debatable.

About this research paper

What this paper is about

Lyme disease is an infectious, multi-system, tick-borne disease caused by genospecies of Borrelia burgdorferi bacteria sensu lato, characterized by remarkable heterogeneity. In this situation choosing an optimal antigen array for diagnostic tests seems problematic. The serological tests for borrelia routinely done in laboratories often produce ambiguous results, which makes a proper diagnosis rather complicated and thus delays the implementation of an appropriate treatment regimen. Thirty-seven outpatients and eight inpatients with suspected borreliosis diagnosis hospitalized at the Clinics of the Pomeranian Medical University (Szczecin, Poland), participated in the study. In order to detect the antibodies against Borrelia sensu lato three kinds of serological tests were used: indirect immunofluorescence assay (IIFA), enzyme-linked immunosorbent assay (ELISA), and immunoblot. The IIFA and immunoblot tests conducted on 45 patients (100%) produced positive results for both the IgM and IgG antibody types. In the case of ELISA, positive or borderline results were observed in only 24 patients (53.3%). The immunoblot test for IgM most frequently detected antibodies against the outer surface protein C (OspC) antigen (p25), and, in the case of IgG, against the recombinant variable surface antigen (VlsE). The IIFA screening test used for diagnosing Lyme borreliosis produced the highest percentage of positive results, which were then confirmed by immunoblot, but not by ELISA. Therefore using only ELISA as a screening test or for diagnosing Lyme borreliosis seems debatable.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Lyme disease is an infectious, multi-system, tick-borne disease caused by genospecies of Borrelia burgdorferi bacteria sensu lato, characterized by remarkable heterogeneity. In this situation choosing an optimal antigen array for diagnostic tests seems problematic. The serological tests for borrelia routinely done in laboratories often produce ambiguous results, which makes a proper diagnosis rather complicated and thus delays the implementation of an appropriate treatment regimen. Thirty-seven outpatients and eight inpatients with suspected borreliosis diagnosis hospitalized at the Clinics of the Pomeranian Medical University (Szczecin, Poland), participated in the study. In order to detect the antibodies against Borrelia sensu lato three kinds of serological tests were used: indirect immunofluorescence assay (IIFA), enzyme-linked immunosorbent assay (ELISA), and immunoblot. The IIFA and immunoblot tests conducted on 45 patients (100%) produced positive results for both the IgM and IgG antibody types. In the case of ELISA, positive or borderline results were observed in only 24 patients (53.3%). The immunoblot test for IgM most frequently detected antibodies against the outer surface protein C (OspC) antigen (p25), and, in the case of IgG, against the recombinant variable surface antigen (VlsE). The IIFA screening test used for diagnosing Lyme borreliosis produced the highest percentage of positive results, which were then confirmed by immunoblot, but not by ELISA. Therefore using only ELISA as a screening test or for diagnosing Lyme borreliosis seems debatable.

Key concepts: Serology, Borrelia burgdorferi, Lyme disease, Borrelia, Antigen, Antibody, Immunology, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Serodiagnosis of Borreliosis: Indirect Immunofluorescence Assay, Enzyme-Linked Immunosorbent Assay and Immunoblotting — Research Paper | ScholarLens