2004•Journal of Structural EngineeringRequires access

Rocking Wall–Frame Structures with Supplemental Tendon Systems

Jack Ajrab, Gökhan Pekcan, John B. Mander

Open publisher page 186 citations

Abstract

This paper introduces the implementation of proposed rocking shear walls—as opposed to conventional fixed-based walls—in frame structures following the principles of the damage avoidance design philosophy. For improved seismic response, rocking walls are coupled with a separate nonload bearing nonlinear supplemental damping system. In view of the typical response of rocking systems, it is proposed that an energy dissipation system is configured and devices are strategically placed to exploit the expected large displacements. A performance-based design methodology is introduced and used to design a six-story rocking wall–frame building with various supplemental system configurations which include prestressed tendons and energy dissipation devices. Seismic performance and response evaluation, using nonlinear time–history analyses, suggests that desired performance levels (minor to no damage) can be achieved with added equivalent viscous damping (∼20%) resulting in reduced floor accelerations interstory drifts. Finally, a sensitivity study on the effect of various system parameters on the performance of the structure showed that the seismic response was not sensitive to the prestress level in tendons and to wall base width. Whereas a draped tendon profile results in a lower and more even distribution of interstory drifts in comparison to those in fixed-based structures.

About this research paper

What this paper is about

This paper introduces the implementation of proposed rocking shear walls—as opposed to conventional fixed-based walls—in frame structures following the principles of the damage avoidance design philosophy. For improved seismic response, rocking walls are coupled with a separate nonload bearing nonlinear supplemental damping system. In view of the typical response of rocking systems, it is proposed that an energy dissipation system is configured and devices are strategically placed to exploit the expected large displacements. A performance-based design methodology is introduced and used to design a six-story rocking wall–frame building with various supplemental system configurations which include prestressed tendons and energy dissipation devices. Seismic performance and response evaluation, using nonlinear time–history analyses, suggests that desired performance levels (minor to no damage) can be achieved with added equivalent viscous damping (∼20%) resulting in reduced floor accelerations interstory drifts. Finally, a sensitivity study on the effect of various system parameters on the performance of the structure showed that the seismic response was not sensitive to the prestress level in tendons and to wall base width. Whereas a draped tendon profile results in a lower and more even distribution of interstory drifts in comparison to those in fixed-based structures.

Why it matters

OpenAlex reports 186 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper introduces the implementation of proposed rocking shear walls—as opposed to conventional fixed-based walls—in frame structures following the principles of the damage avoidance design philosophy. For improved seismic response, rocking walls are coupled with a separate nonload bearing nonlinear supplemental damping system. In view of the typical response of rocking systems, it is proposed that an energy dissipation system is configured and devices are strategically placed to exploit the expected large displacements. A performance-based design methodology is introduced and used to design a six-story rocking wall–frame building with various supplemental system configurations which include prestressed tendons and energy dissipation devices. Seismic performance and response evaluation, using nonlinear time–history analyses, suggests that desired performance levels (minor to no damage) can be achieved with added equivalent viscous damping (∼20%) resulting in reduced floor accelerations interstory drifts. Finally, a sensitivity study on the effect of various system parameters on the performance of the structure showed that the seismic response was not sensitive to the prestress level in tendons and to wall base width. Whereas a draped tendon profile results in a lower and more even distribution of interstory drifts in comparison to those in fixed-based structures.

Key concepts: Structural engineering, Dissipation, Shear wall, Nonlinear system, Frame (networking), Engineering, Structural system, Mechanical engineering