2010Journal of Fluids EngineeringRequires access

Prediction of the Nonuniform Tip Clearance Effect on the Axial Compressor Flow Field

Young-Seok Kang, Shin-Hyoung Kang

Open publisher page 23 citations

Abstract

It is well-known that nonuniform tip clearance in an axial compressor induces pressure and velocity perturbations along the circumferential direction. This study develops a numerical modeling to predict perturbed flows in an axial compressor with a nonuniform tip clearance and presents a mechanism of the flow redistribution in the axial compressor at design and off-design conditions. The modeling results are compared with CFD results (2006, “Prediction of the Fluid Induced Instability Force of an Axial Compressor,” ASME FEDSM 2006, Miami, FL) not only to validate the present modeling, but also to investigate more detailed flow fields. In an axial compressor, nonuniform tip clearance varies local flow passage area and resultant axial velocity along the circumferential direction. There are small axial velocity differences between maximum and minimum clearances near the design condition, while large pressure differences are investigated according to local locations. However, contribution of the main flow region overrides the tip clearance effect as the flow coefficient deviates from the design condition. Moreover, the flow field redistribution becomes noticeably strong when the off-design effects are incorporated. In case of high flow coefficients, the low relative flow angle near the minimum clearance regions results in a large negative incidence angle and forms a large flow recirculation region and a corresponding large amount of loss occurs near the blade pressure surface. It further promotes strong flow field perturbations at the off-design conditions. The integration of these pressure and blade loading perturbations with a control volume analysis leads to the well-known Alford’s force. Alford’s force is always negative near the design condition; however, it reverses its sign to positive at the high flow coefficients. At the high flow coefficients, tip leakage flow effects lessen, while increased off-design effects amplify blade loading perturbations and a steep increase in Alford’s force. This study enables that nonuniform flow field, and the resultant Alford’s force, which may result in an unstable rotor-dynamic behavior, can be easily evaluated and assessed during the compressor, fan, or blower design process.

About this research paper

What this paper is about

It is well-known that nonuniform tip clearance in an axial compressor induces pressure and velocity perturbations along the circumferential direction. This study develops a numerical modeling to predict perturbed flows in an axial compressor with a nonuniform tip clearance and presents a mechanism of the flow redistribution in the axial compressor at design and off-design conditions. The modeling results are compared with CFD results (2006, “Prediction of the Fluid Induced Instability Force of an Axial Compressor,” ASME FEDSM 2006, Miami, FL) not only to validate the present modeling, but also to investigate more detailed flow fields. In an axial compressor, nonuniform tip clearance varies local flow passage area and resultant axial velocity along the circumferential direction. There are small axial velocity differences between maximum and minimum clearances near the design condition, while large pressure differences are investigated according to local locations. However, contribution of the main flow region overrides the tip clearance effect as the flow coefficient deviates from the design condition. Moreover, the flow field redistribution becomes noticeably strong when the off-design effects are incorporated. In case of high flow coefficients, the low relative flow angle near the minimum clearance regions results in a large negative incidence angle and forms a large flow recirculation region and a corresponding large amount of loss occurs near the blade pressure surface. It further promotes strong flow field perturbations at the off-design conditions. The integration of these pressure and blade loading perturbations with a control volume analysis leads to the well-known Alford’s force. Alford’s force is always negative near the design condition; however, it reverses its sign to positive at the high flow coefficients. At the high flow coefficients, tip leakage flow effects lessen, while increased off-design effects amplify blade loading perturbations and a steep increase in Alford’s force. This study enables that nonuniform flow field, and the resultant Alford’s force, which may result in an unstable rotor-dynamic behavior, can be easily evaluated and assessed during the compressor, fan, or blower design process.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It is well-known that nonuniform tip clearance in an axial compressor induces pressure and velocity perturbations along the circumferential direction. This study develops a numerical modeling to predict perturbed flows in an axial compressor with a nonuniform tip clearance and presents a mechanism of the flow redistribution in the axial compressor at design and off-design conditions. The modeling results are compared with CFD results (2006, “Prediction of the Fluid Induced Instability Force of an Axial Compressor,” ASME FEDSM 2006, Miami, FL) not only to validate the present modeling, but also to investigate more detailed flow fields. In an axial compressor, nonuniform tip clearance varies local flow passage area and resultant axial velocity along the circumferential direction. There are small axial velocity differences between maximum and minimum clearances near the design condition, while large pressure differences are investigated according to local locations. However, contribution of the main flow region overrides the tip clearance effect as the flow coefficient deviates from the design condition. Moreover, the flow field redistribution becomes noticeably strong when the off-design effects are incorporated. In case of high flow coefficients, the low relative flow angle near the minimum clearance regions results in a large negative incidence angle and forms a large flow recirculation region and a corresponding large amount of loss occurs near the blade pressure surface. It further promotes strong flow field perturbations at the off-design conditions. The integration of these pressure and blade loading perturbations with a control volume analysis leads to the well-known Alford’s force. Alford’s force is always negative near the design condition; however, it reverses its sign to positive at the high flow coefficients. At the high flow coefficients, tip leakage flow effects lessen, while increased off-design effects amplify blade loading perturbations and a steep increase in Alford’s force. This study enables that nonuniform flow field, and the resultant Alford’s force, which may result in an unstable rotor-dynamic behavior, can be easily evaluated and assessed during the compressor, fan, or blower design process.

Key concepts: Axial compressor, Tip clearance, Mechanics, Gas compressor, Computational fluid dynamics, Flow (mathematics), Materials science, Internal flow

Related papers

Back to paper searchBrowse research topicsOriginal source
Prediction of the Nonuniform Tip Clearance Effect on the Axial Compressor Flow Field — Research Paper | ScholarLens