2004Investigative RadiologyRequires access

Evaluation of Semiautomated Internal Carotid Artery Stenosis Quantification from 3-Dimensional Contrast-Enhanced Magnetic Resonance Angiograms

Cornelis M. van Bemmel, Otto E. H. Elgersma, Evert‐Jan Vonken, Marco Fiorelli, Maarten S. van Leeuwen, Wiro J. Niessen

Open publisher page 13 citations

Abstract

RATIONALE AND OBJECTIVES: The performance of a semiautomatic technique for internal carotid artery (ICA) stenosis quantification of the internal carotid artery in contrast-enhanced magnetic resonance angiography was evaluated. MATERIALS AND METHODS: The degree of stenosis of 52 ICAs was quantified by measuring the cross-sectional area along the center lumen line. This was performed both by 3 independent observers and the semiautomated method. The degree of stenosis was defined as the amount of cross-sectional lumen reduction. RESULTS: Agreement between the method and observers was good (weighted-kappa, kappaW = 0.89). Reproducibility of measurements of the semiautomated technique was better (kappaW = 0.97) than that of the observers (kappaW = 0.76), and the evaluated technique was considerably less time-consuming. CONCLUSIONS: Because the user interaction is limited, this technique can be used to replace an expert observer in 3-dimensional stenosis quantification of the ICA at CE-MRA in clinical practice.

About this research paper

What this paper is about

RATIONALE AND OBJECTIVES: The performance of a semiautomatic technique for internal carotid artery (ICA) stenosis quantification of the internal carotid artery in contrast-enhanced magnetic resonance angiography was evaluated. MATERIALS AND METHODS: The degree of stenosis of 52 ICAs was quantified by measuring the cross-sectional area along the center lumen line. This was performed both by 3 independent observers and the semiautomated method. The degree of stenosis was defined as the amount of cross-sectional lumen reduction. RESULTS: Agreement between the method and observers was good (weighted-kappa, kappaW = 0.89). Reproducibility of measurements of the semiautomated technique was better (kappaW = 0.97) than that of the observers (kappaW = 0.76), and the evaluated technique was considerably less time-consuming. CONCLUSIONS: Because the user interaction is limited, this technique can be used to replace an expert observer in 3-dimensional stenosis quantification of the ICA at CE-MRA in clinical practice.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

RATIONALE AND OBJECTIVES: The performance of a semiautomatic technique for internal carotid artery (ICA) stenosis quantification of the internal carotid artery in contrast-enhanced magnetic resonance angiography was evaluated. MATERIALS AND METHODS: The degree of stenosis of 52 ICAs was quantified by measuring the cross-sectional area along the center lumen line. This was performed both by 3 independent observers and the semiautomated method. The degree of stenosis was defined as the amount of cross-sectional lumen reduction. RESULTS: Agreement between the method and observers was good (weighted-kappa, kappaW = 0.89). Reproducibility of measurements of the semiautomated technique was better (kappaW = 0.97) than that of the observers (kappaW = 0.76), and the evaluated technique was considerably less time-consuming. CONCLUSIONS: Because the user interaction is limited, this technique can be used to replace an expert observer in 3-dimensional stenosis quantification of the ICA at CE-MRA in clinical practice.

Key concepts: Magnetic resonance imaging, Stenosis, Contrast (vision), Medicine, Magnetic resonance angiography, Internal carotid artery, Carotid arteries, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Semiautomated Internal Carotid Artery Stenosis Quantification from 3-Dimensional Contrast-Enhanced Magnetic Resonance Angiograms — Research Paper | ScholarLens