HPLC Determination and MS Confirmation of Malachite Green, Gentian Violet, and Their Leuco Metabolite Residues in Channel Catfish Muscle
Guoying Chen, Shui Miao
Abstract
Guoying Chen, Shui Miao
Abstract
Residues of malachite green (MG), gentian violet (GV), and their leuco metabolites in channel catfish muscle were individually determined by HPLC using diode array and fluorescence detectors and confirmed by tandem mass spectrometry. This detection scheme obviates a PbO(2) reactor that converts leuco forms to chromatic forms for absorbance detection, therefore eliminating uncertainties in oxidant depletion and data integrity. Extraction was performed once in pH 3 McIlvaine buffer and acetonitrile, followed by cleanup using a polymeric strong cation-exchange column. Liquid-liquid extraction was excluded to provide an environmentally responsible and relatively rapid protocol. Spectrometric limits of detection (LOD; S/N = 3) for MG (lambda = 620 nm) and GV (lambda = 588 nm) were 0.38 and 0.26 ng/g with 44.5-49.2% and 92.2-101.4% recoveries (1-10 ng/g, n = 6), respectively. Fluorometric LOD (S/N = 3) for LMG and LGV (lambda(ex) = 266 nm, lambda(em) = 360 nm) were 0.10 and 0.09 ng/g with 74.3-84.5% and 80.6-86.5% recoveries (1-10 ng/g, n = 6), respectively. This simplified protocol saves costs and meets the sensitivity requirements set by the Food and Drug Administration and the European Union.
OpenAlex reports 110 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Residues of malachite green (MG), gentian violet (GV), and their leuco metabolites in channel catfish muscle were individually determined by HPLC using diode array and fluorescence detectors and confirmed by tandem mass spectrometry. This detection scheme obviates a PbO(2) reactor that converts leuco forms to chromatic forms for absorbance detection, therefore eliminating uncertainties in oxidant depletion and data integrity. Extraction was performed once in pH 3 McIlvaine buffer and acetonitrile, followed by cleanup using a polymeric strong cation-exchange column. Liquid-liquid extraction was excluded to provide an environmentally responsible and relatively rapid protocol. Spectrometric limits of detection (LOD; S/N = 3) for MG (lambda = 620 nm) and GV (lambda = 588 nm) were 0.38 and 0.26 ng/g with 44.5-49.2% and 92.2-101.4% recoveries (1-10 ng/g, n = 6), respectively. Fluorometric LOD (S/N = 3) for LMG and LGV (lambda(ex) = 266 nm, lambda(em) = 360 nm) were 0.10 and 0.09 ng/g with 74.3-84.5% and 80.6-86.5% recoveries (1-10 ng/g, n = 6), respectively. This simplified protocol saves costs and meets the sensitivity requirements set by the Food and Drug Administration and the European Union.
Key concepts: Malachite green, Chemistry, Chromatography, Absorbance, Metabolite, Detection limit, Catfish, High-performance liquid chromatography