2001Analytical ChemistryRequires access

Determination of Steroid Estrogens in Wastewater by Immunoaffinity Extraction Coupled with HPLC−Electrospray-MS

P. Lee Ferguson, Charles R. Iden, Anne E. McElroy, Bruce J. Brownawell

Open publisher page 138 citations

Abstract

A new method, based on immunoaffinity extraction coupled with liquid chromatography/electrospray mass spectrometry (LC/ESI-MS) is described for the determination of the steroid estrogens beta-estradiol (E2), estrone (E1), and alpha-ethynylestradiol (E2) in wastewater. The use of highly selective immunosorbents in sample preparation prior to analysis allows the removal of interfering sample matrix compounds present in the wastewater extracts that would otherwise cause severe ionization suppression of the estrogens during the electrospray process. In addition, immunoextraction removes much of the isobaric noise from the selected ion monitoring chromatograms, increasing the signal-to-noise ratios for analytes, and contributing to the low detection limits (0.18 and 0.07 ng/L for E2 and E1, respectively) achieved by the current method. The method was applied to analysis of estrogens in two wastewater effluents. Recoveries of E2 and E1 were excellent (>90%), while the nonimmunogen (but structurally related) analyte EE2 was not retained (recovery <2%) from effluent extracts by the immunosorbent. This illustrates the extreme selectivity of the immunoextraction purification step. Precision of the method was high, with relative standard deviations below 5%. Concentrations of E2 in wastewater varied from 0.77 to 6.4 ng/L, while concentrations of E1 were greater (1.6-18 ng/L).

About this research paper

What this paper is about

A new method, based on immunoaffinity extraction coupled with liquid chromatography/electrospray mass spectrometry (LC/ESI-MS) is described for the determination of the steroid estrogens beta-estradiol (E2), estrone (E1), and alpha-ethynylestradiol (E2) in wastewater. The use of highly selective immunosorbents in sample preparation prior to analysis allows the removal of interfering sample matrix compounds present in the wastewater extracts that would otherwise cause severe ionization suppression of the estrogens during the electrospray process. In addition, immunoextraction removes much of the isobaric noise from the selected ion monitoring chromatograms, increasing the signal-to-noise ratios for analytes, and contributing to the low detection limits (0.18 and 0.07 ng/L for E2 and E1, respectively) achieved by the current method. The method was applied to analysis of estrogens in two wastewater effluents. Recoveries of E2 and E1 were excellent (>90%), while the nonimmunogen (but structurally related) analyte EE2 was not retained (recovery <2%) from effluent extracts by the immunosorbent. This illustrates the extreme selectivity of the immunoextraction purification step. Precision of the method was high, with relative standard deviations below 5%. Concentrations of E2 in wastewater varied from 0.77 to 6.4 ng/L, while concentrations of E1 were greater (1.6-18 ng/L).

Why it matters

OpenAlex reports 138 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method, based on immunoaffinity extraction coupled with liquid chromatography/electrospray mass spectrometry (LC/ESI-MS) is described for the determination of the steroid estrogens beta-estradiol (E2), estrone (E1), and alpha-ethynylestradiol (E2) in wastewater. The use of highly selective immunosorbents in sample preparation prior to analysis allows the removal of interfering sample matrix compounds present in the wastewater extracts that would otherwise cause severe ionization suppression of the estrogens during the electrospray process. In addition, immunoextraction removes much of the isobaric noise from the selected ion monitoring chromatograms, increasing the signal-to-noise ratios for analytes, and contributing to the low detection limits (0.18 and 0.07 ng/L for E2 and E1, respectively) achieved by the current method. The method was applied to analysis of estrogens in two wastewater effluents. Recoveries of E2 and E1 were excellent (>90%), while the nonimmunogen (but structurally related) analyte EE2 was not retained (recovery <2%) from effluent extracts by the immunosorbent. This illustrates the extreme selectivity of the immunoextraction purification step. Precision of the method was high, with relative standard deviations below 5%. Concentrations of E2 in wastewater varied from 0.77 to 6.4 ng/L, while concentrations of E1 were greater (1.6-18 ng/L).

Key concepts: Chemistry, Chromatography, Analyte, Electrospray ionization, Electrospray, Wastewater, Mass spectrometry, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Steroid Estrogens in Wastewater by Immunoaffinity Extraction Coupled with HPLC−Electrospray-MS — Research Paper | ScholarLens