2002Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

Quantitative Doppler ultrasound-based determination of volumetric blood flow

Jun S. Ha, John A. Hossack

Open publisher page 1 citations

Abstract

Conventional ultrasound Doppler velocity measurements are scaled by the cosine of the angle between the blood flow axis and ultrasound beam axis. In the approach used here, a transducer array was used to acquire a first cross-sectional Doppler data set of the vessel under examination. The transducer array was then moved to a different angle to acquire a second cross-sectional Doppler data set. Thereafter, we used the known angle between the two arrays ultrasound beams and the cosine (theta) scaled Doppler estimates to solve for the true angle between the blood flow axis and ultrasound beam axis of the first data set. Upon integrating the angle corrected velocity estimates over the entire vessel cross-section, we were able to estimate blood volume flow rate. The performance of the new approach was tested in a flow phantom that was designed to provide a constant flow in a simulated vessel. The data were collected for two sets of angles and three different flow velocities for each angle set. The unknown Doppler angle was calculated from the data and used to correct the flow velocity.

About this research paper

What this paper is about

Conventional ultrasound Doppler velocity measurements are scaled by the cosine of the angle between the blood flow axis and ultrasound beam axis. In the approach used here, a transducer array was used to acquire a first cross-sectional Doppler data set of the vessel under examination. The transducer array was then moved to a different angle to acquire a second cross-sectional Doppler data set. Thereafter, we used the known angle between the two arrays ultrasound beams and the cosine (theta) scaled Doppler estimates to solve for the true angle between the blood flow axis and ultrasound beam axis of the first data set. Upon integrating the angle corrected velocity estimates over the entire vessel cross-section, we were able to estimate blood volume flow rate. The performance of the new approach was tested in a flow phantom that was designed to provide a constant flow in a simulated vessel. The data were collected for two sets of angles and three different flow velocities for each angle set. The unknown Doppler angle was calculated from the data and used to correct the flow velocity.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Conventional ultrasound Doppler velocity measurements are scaled by the cosine of the angle between the blood flow axis and ultrasound beam axis. In the approach used here, a transducer array was used to acquire a first cross-sectional Doppler data set of the vessel under examination. The transducer array was then moved to a different angle to acquire a second cross-sectional Doppler data set. Thereafter, we used the known angle between the two arrays ultrasound beams and the cosine (theta) scaled Doppler estimates to solve for the true angle between the blood flow axis and ultrasound beam axis of the first data set. Upon integrating the angle corrected velocity estimates over the entire vessel cross-section, we were able to estimate blood volume flow rate. The performance of the new approach was tested in a flow phantom that was designed to provide a constant flow in a simulated vessel. The data were collected for two sets of angles and three different flow velocities for each angle set. The unknown Doppler angle was calculated from the data and used to correct the flow velocity.

Key concepts: Doppler effect, Transducer, Blood flow, Ultrasonic flow meter, Imaging phantom, Ultrasound, Flow (mathematics), Flow velocity

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitative Doppler ultrasound-based determination of volumetric blood flow — Research Paper | ScholarLens