2001Optics ExpressOpen access

Polarization errors associated with zero-order achromatic quarter-wave plates in the whole visible spectral range

Bruno Boulbry, Bruno Bousquet, Bernard Le Jeune, Y. Guern, J Lotrian

Open full text 54 citations

Abstract

By a combination of quarter-wave plates made of different birefringent materials it is possible to produce achromatic quarter-wave plates whose degree of achromatism is dependant on the dispersions of birefringence and on the thicknesses of the individual quarter-wave plates. These waveplates are widely used in optical instrumentation and the residual errors associated with these devices can be very important in high resolution spectro-polarimetry measurements. The misalignment of optic axis in a double crystal waveplate is one of the main source of error and leads to elliptical eigenpolarization modes in the retarder and the oscillation of its orientation according to the wavelength. This paper will discuss, first, how the characteristics of a quartz-MgF2 quarter-wave plate is affected by such a misalignment. A correlation with the experiment is then achieved in order to highlight the interest of taking a possible tilt error into consideration when doing polarimetric measurements.

About this research paper

What this paper is about

By a combination of quarter-wave plates made of different birefringent materials it is possible to produce achromatic quarter-wave plates whose degree of achromatism is dependant on the dispersions of birefringence and on the thicknesses of the individual quarter-wave plates. These waveplates are widely used in optical instrumentation and the residual errors associated with these devices can be very important in high resolution spectro-polarimetry measurements. The misalignment of optic axis in a double crystal waveplate is one of the main source of error and leads to elliptical eigenpolarization modes in the retarder and the oscillation of its orientation according to the wavelength. This paper will discuss, first, how the characteristics of a quartz-MgF2 quarter-wave plate is affected by such a misalignment. A correlation with the experiment is then achieved in order to highlight the interest of taking a possible tilt error into consideration when doing polarimetric measurements.

Why it matters

OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

By a combination of quarter-wave plates made of different birefringent materials it is possible to produce achromatic quarter-wave plates whose degree of achromatism is dependant on the dispersions of birefringence and on the thicknesses of the individual quarter-wave plates. These waveplates are widely used in optical instrumentation and the residual errors associated with these devices can be very important in high resolution spectro-polarimetry measurements. The misalignment of optic axis in a double crystal waveplate is one of the main source of error and leads to elliptical eigenpolarization modes in the retarder and the oscillation of its orientation according to the wavelength. This paper will discuss, first, how the characteristics of a quartz-MgF2 quarter-wave plate is affected by such a misalignment. A correlation with the experiment is then achieved in order to highlight the interest of taking a possible tilt error into consideration when doing polarimetric measurements.

Key concepts: Waveplate, Achromatic lens, Optics, Birefringence, Polarimetry, Polarization (electrochemistry), Wavelength, Tilt (camera)

Related papers

Back to paper searchBrowse research topicsOriginal source
Polarization errors associated with zero-order achromatic quarter-wave plates in the whole visible spectral range — Research Paper | ScholarLens