Experimental Study on Improved Beam-to-Column Connections of Steel Moment Frame
Yan Xia Zhang, Lu Yao Wang, Fan Yang
Abstract
Yan Xia Zhang, Lu Yao Wang, Fan Yang
Abstract
Five different full-scale improved beam-to-column connections in steel moment frame were tested to study the failure process, failure mode, strength and plastic deformation capacity. The speciments consisted of one Welded-Bolted Widen Flange-Dog Bone Connection(SP1-1), one Welded Widen Flange-Dog Bone Connection(SP1-2),one T-Widen Flange Connection(SP2),one Beam Strengthen-Flange Splice Plate Reduced Connection(Reduced depth=0)(SP3-1),one Beam Strengthen-Flange Splice Plate Reduced Connection(Reduced depth=50mm)(SP3-2). The test showed that the five connections effectively moved the plastic hinges away from the face of the column so that end welding of beam would be effectively protected, the ultimate plastic rotation of connection exceeded 0.03rad, ductility factor is large than 4 and hysteresis loop is full .these connections provided good plastic deformation and energy dissipation.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Five different full-scale improved beam-to-column connections in steel moment frame were tested to study the failure process, failure mode, strength and plastic deformation capacity. The speciments consisted of one Welded-Bolted Widen Flange-Dog Bone Connection(SP1-1), one Welded Widen Flange-Dog Bone Connection(SP1-2),one T-Widen Flange Connection(SP2),one Beam Strengthen-Flange Splice Plate Reduced Connection(Reduced depth=0)(SP3-1),one Beam Strengthen-Flange Splice Plate Reduced Connection(Reduced depth=50mm)(SP3-2). The test showed that the five connections effectively moved the plastic hinges away from the face of the column so that end welding of beam would be effectively protected, the ultimate plastic rotation of connection exceeded 0.03rad, ductility factor is large than 4 and hysteresis loop is full .these connections provided good plastic deformation and energy dissipation.
Key concepts: Flange, Structural engineering, Welding, Connection (principal bundle), Ductility (Earth science), Materials science, Beam (structure), Plastic hinge