2002Anesthesia & AnalgesiaRequires access

Fentanyl Attenuates the Hemodynamic Response to Endotracheal Intubation More Than the Response to Laryngoscopy

Yushi Adachi, Maiko Satomoto, Hideyuki Higuchi, Kazuhiko Watanabe

Open publisher page 98 citations

Abstract

UNLABELLED: We examined the effectiveness of avoiding laryngoscopy in reducing the hemodynamic responses to orotracheal intubation during the induction of anesthesia. One hundred surgical patients who required orotracheal intubation were randomly allocated into four groups. The first and third groups underwent fiberoptic intubation, in which an anesthesiologist inserted the endotracheal tube into the trachea under TV monitoring through a bronchoscope, and the second and fourth groups underwent conventional orotracheal intubation using a rigid laryngoscope. The third and fourth groups were pretreated with 2 microg/kg fentanyl IV immediately before the induction of anesthesia. Blood pressure and heart rate were measured noninvasively. A significant reduction in hemodynamic response was seen in only the group treated with fentanyl and intubated using the fiberoptic technique. Without fentanyl, there was no significant difference in hemodynamic changes between the groups. We conclude that the administration of fentanyl suppresses the hemodynamic responses to endotracheal intubation more than it does to laryngoscopy. There was no significant difference in the hemodynamic responses to orotracheal intubation by fiberscopy and laryngoscopy without fentanyl pretreatment, whereas 2 microg/kg fentanyl significantly reduced the hemodynamic responses in the group intubated by fiberscopy. IMPLICATIONS: We assessed the effectiveness of avoiding laryngoscopy for orotracheal intubation. There was no significant difference in the hemodynamic responses to orotracheal intubation by fiberscopy and laryngoscopy without fentanyl pretreatment, whereas 2 microg/kg fentanyl significantly reduced the hemodynamic responses in the group intubated by fiberscopy. Pretreatment of fentanyl and fiberoptic intubation might be recommended for avoiding hyperdynamic responses.

About this research paper

What this paper is about

UNLABELLED: We examined the effectiveness of avoiding laryngoscopy in reducing the hemodynamic responses to orotracheal intubation during the induction of anesthesia. One hundred surgical patients who required orotracheal intubation were randomly allocated into four groups. The first and third groups underwent fiberoptic intubation, in which an anesthesiologist inserted the endotracheal tube into the trachea under TV monitoring through a bronchoscope, and the second and fourth groups underwent conventional orotracheal intubation using a rigid laryngoscope. The third and fourth groups were pretreated with 2 microg/kg fentanyl IV immediately before the induction of anesthesia. Blood pressure and heart rate were measured noninvasively. A significant reduction in hemodynamic response was seen in only the group treated with fentanyl and intubated using the fiberoptic technique. Without fentanyl, there was no significant difference in hemodynamic changes between the groups. We conclude that the administration of fentanyl suppresses the hemodynamic responses to endotracheal intubation more than it does to laryngoscopy. There was no significant difference in the hemodynamic responses to orotracheal intubation by fiberscopy and laryngoscopy without fentanyl pretreatment, whereas 2 microg/kg fentanyl significantly reduced the hemodynamic responses in the group intubated by fiberscopy. IMPLICATIONS: We assessed the effectiveness of avoiding laryngoscopy for orotracheal intubation. There was no significant difference in the hemodynamic responses to orotracheal intubation by fiberscopy and laryngoscopy without fentanyl pretreatment, whereas 2 microg/kg fentanyl significantly reduced the hemodynamic responses in the group intubated by fiberscopy. Pretreatment of fentanyl and fiberoptic intubation might be recommended for avoiding hyperdynamic responses.

Why it matters

OpenAlex reports 98 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

UNLABELLED: We examined the effectiveness of avoiding laryngoscopy in reducing the hemodynamic responses to orotracheal intubation during the induction of anesthesia. One hundred surgical patients who required orotracheal intubation were randomly allocated into four groups. The first and third groups underwent fiberoptic intubation, in which an anesthesiologist inserted the endotracheal tube into the trachea under TV monitoring through a bronchoscope, and the second and fourth groups underwent conventional orotracheal intubation using a rigid laryngoscope. The third and fourth groups were pretreated with 2 microg/kg fentanyl IV immediately before the induction of anesthesia. Blood pressure and heart rate were measured noninvasively. A significant reduction in hemodynamic response was seen in only the group treated with fentanyl and intubated using the fiberoptic technique. Without fentanyl, there was no significant difference in hemodynamic changes between the groups. We conclude that the administration of fentanyl suppresses the hemodynamic responses to endotracheal intubation more than it does to laryngoscopy. There was no significant difference in the hemodynamic responses to orotracheal intubation by fiberscopy and laryngoscopy without fentanyl pretreatment, whereas 2 microg/kg fentanyl significantly reduced the hemodynamic responses in the group intubated by fiberscopy. IMPLICATIONS: We assessed the effectiveness of avoiding laryngoscopy for orotracheal intubation. There was no significant difference in the hemodynamic responses to orotracheal intubation by fiberscopy and laryngoscopy without fentanyl pretreatment, whereas 2 microg/kg fentanyl significantly reduced the hemodynamic responses in the group intubated by fiberscopy. Pretreatment of fentanyl and fiberoptic intubation might be recommended for avoiding hyperdynamic responses.

Key concepts: Medicine, Laryngoscopy, Fentanyl, Anesthesia, Intubation, Hemodynamics, Orotracheal intubation, Haemodynamic response

Related papers

Back to paper searchBrowse research topicsOriginal source
Fentanyl Attenuates the Hemodynamic Response to Endotracheal Intubation More Than the Response to Laryngoscopy — Research Paper | ScholarLens