1989•Journal of Mass SpectrometryRequires access

Determination of the new aromatase inhibitor CGS 16 949 in biological fluids by capillary gas chromatography/mass spectrometry

Roland Ackermann, Günther Kaiser

Open publisher page 4 citations

Abstract

A specific and sensitive gas chromatographic/mass spectrometric method was developed and validated for the quantitative determination of the aromatase inhibitor CGS 16 949 in plasma and urine. A deuterium-labelled analogue of CGS 16 949 was used as internal standard. The analysis of spiked samples demonstrated the good accuracy and precision of the method. For both plasma and urine, the limit of quantification (LOQ: coefficient of variation (CV) = 10%) and the limit of detection (LOD: CV = 100%) were estimated to be 5 and 1 nmol l-1, respectively. The method was applied to the determination of unchanged CGS 16 949 in plasma and urine of a healthy volunteer orally dosed with 1 mg of CGS 16 949 A.

About this research paper

What this paper is about

A specific and sensitive gas chromatographic/mass spectrometric method was developed and validated for the quantitative determination of the aromatase inhibitor CGS 16 949 in plasma and urine. A deuterium-labelled analogue of CGS 16 949 was used as internal standard. The analysis of spiked samples demonstrated the good accuracy and precision of the method. For both plasma and urine, the limit of quantification (LOQ: coefficient of variation (CV) = 10%) and the limit of detection (LOD: CV = 100%) were estimated to be 5 and 1 nmol l-1, respectively. The method was applied to the determination of unchanged CGS 16 949 in plasma and urine of a healthy volunteer orally dosed with 1 mg of CGS 16 949 A.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A specific and sensitive gas chromatographic/mass spectrometric method was developed and validated for the quantitative determination of the aromatase inhibitor CGS 16 949 in plasma and urine. A deuterium-labelled analogue of CGS 16 949 was used as internal standard. The analysis of spiked samples demonstrated the good accuracy and precision of the method. For both plasma and urine, the limit of quantification (LOQ: coefficient of variation (CV) = 10%) and the limit of detection (LOD: CV = 100%) were estimated to be 5 and 1 nmol l-1, respectively. The method was applied to the determination of unchanged CGS 16 949 in plasma and urine of a healthy volunteer orally dosed with 1 mg of CGS 16 949 A.

Key concepts: Chromatography, Detection limit, Chemistry, Urine, Coefficient of variation, Mass spectrometry, Gas chromatography, Gas chromatography–mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of the new aromatase inhibitor CGS 16 949 in biological fluids by capillary gas chromatography/mass spectrometry — Research Paper | ScholarLens