1981•Diabetes CareRequires access

Intravenous Home Blood Glucose Monitoring

David S. Schade, Robert Philip Eaton, Wiliam J Mitchell, Neal M. Friedman

Open publisher page 9 citations

Abstract

This study examines the correlation between the blood glucose concentration estimated by diabetic subjects at home using a Chemstrip bG reagent strip, and the blood glucose concentration subsequently measured in a Beckman glucose analyzer. Blood samples were obtained by eight diabetic patients throughout a period of 30 days in the home environment. Using the technique of i.v. blood withdrawal, a 250-microliters portion of each blood sample was stored for later physician verification of the blood glucose concentration. The preservative in these stored sampled inhibited the utilization of glucose in the blood samples for at least 30 days. Our results demonstrate that in the home setting, a highly significant correlation (R = 0.85, P less than 0.001) can be obtained between the plasma glucose concentration as estimated by Chemstrip bGs and the blood glucose concentration as estimated by Beckman automated glucose analysis. However, within the diabetic group, marked variation existed in correlation coefficients such that the highest correlation coefficient was 0.94, and the lowest was 0.72. Furthermore, the use of Chemstrip bGs tends to influence a patient's reading toward the preselected color chart of glucose concentration on the Chemstrip bG label. We conclude that i.v. home blood glucose monitoring provides a method whereby the physician can assess the accuracy with which his patients can monitor their blood glucose concentrations in a home environment.

About this research paper

What this paper is about

This study examines the correlation between the blood glucose concentration estimated by diabetic subjects at home using a Chemstrip bG reagent strip, and the blood glucose concentration subsequently measured in a Beckman glucose analyzer. Blood samples were obtained by eight diabetic patients throughout a period of 30 days in the home environment. Using the technique of i.v. blood withdrawal, a 250-microliters portion of each blood sample was stored for later physician verification of the blood glucose concentration. The preservative in these stored sampled inhibited the utilization of glucose in the blood samples for at least 30 days. Our results demonstrate that in the home setting, a highly significant correlation (R = 0.85, P less than 0.001) can be obtained between the plasma glucose concentration as estimated by Chemstrip bGs and the blood glucose concentration as estimated by Beckman automated glucose analysis. However, within the diabetic group, marked variation existed in correlation coefficients such that the highest correlation coefficient was 0.94, and the lowest was 0.72. Furthermore, the use of Chemstrip bGs tends to influence a patient's reading toward the preselected color chart of glucose concentration on the Chemstrip bG label. We conclude that i.v. home blood glucose monitoring provides a method whereby the physician can assess the accuracy with which his patients can monitor their blood glucose concentrations in a home environment.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study examines the correlation between the blood glucose concentration estimated by diabetic subjects at home using a Chemstrip bG reagent strip, and the blood glucose concentration subsequently measured in a Beckman glucose analyzer. Blood samples were obtained by eight diabetic patients throughout a period of 30 days in the home environment. Using the technique of i.v. blood withdrawal, a 250-microliters portion of each blood sample was stored for later physician verification of the blood glucose concentration. The preservative in these stored sampled inhibited the utilization of glucose in the blood samples for at least 30 days. Our results demonstrate that in the home setting, a highly significant correlation (R = 0.85, P less than 0.001) can be obtained between the plasma glucose concentration as estimated by Chemstrip bGs and the blood glucose concentration as estimated by Beckman automated glucose analysis. However, within the diabetic group, marked variation existed in correlation coefficients such that the highest correlation coefficient was 0.94, and the lowest was 0.72. Furthermore, the use of Chemstrip bGs tends to influence a patient's reading toward the preselected color chart of glucose concentration on the Chemstrip bG label. We conclude that i.v. home blood glucose monitoring provides a method whereby the physician can assess the accuracy with which his patients can monitor their blood glucose concentrations in a home environment.

Key concepts: Medicine, Diabetes mellitus, Preservative, Blood glucose monitoring, Plasma glucose, Blood Glucose Self-Monitoring, Internal medicine, Endocrinology

Related papers

Back to paper searchBrowse research topicsOriginal source
Intravenous Home Blood Glucose Monitoring — Research Paper | ScholarLens