2000Drug Development and Industrial PharmacyRequires access

Comparing HPLC and UV Spectrophotometric Analysis Methods for Determining the Stability of Sorbic Acid in Nonionic Creams Containing Lactic Acid

Melgardt M. de Villiers, Jacobus J. Bergh

Open publisher page 17 citations

Abstract

This paper describes a comparison between ultraviolet (UV) spectrophotometric and high-performance liquid chromatographic (HPLC) methods of analysis for the determination of sorbic acid in nonionic creams containing lactic acid. Sorbic acid is an antimycotic agent and is used as a preservative in pharmaceuticals, cosmetics, and food products. UV spectrophotometric analysis was done by calculating the concentration of remaining sorbic acid from the absorbance values and the molar extinction coefficient EM258 = 24,080. A decrease in absorbance at 258 nm was accompanied by a simultaneous increase in total carbonyls and monoaldehyde content and the appearance of a very weak absorption maximum between 215 and 225 nm. HPLC analysis was done with a Hypersil BDS C8 column with detection at 254 nm and employing a mobile phase consisting of a mixture of buffer and methanol (7:3 v/v) at a pH of 2.25. The buffer consisted of 0.85% H2SO4 in 17.5 mM KH2PO4. The validation results, together with statistical treatment of the data, demonstrated the reliability of both procedures. A drawback of the UV methods was, however, its lack of adequate measurement of sorbic acid stability at higher temperatures. For these assays, the HPLC method was found to be adequate, and it should therefore be used to obtain accurate stability data for sorbic acid in creams.

About this research paper

What this paper is about

This paper describes a comparison between ultraviolet (UV) spectrophotometric and high-performance liquid chromatographic (HPLC) methods of analysis for the determination of sorbic acid in nonionic creams containing lactic acid. Sorbic acid is an antimycotic agent and is used as a preservative in pharmaceuticals, cosmetics, and food products. UV spectrophotometric analysis was done by calculating the concentration of remaining sorbic acid from the absorbance values and the molar extinction coefficient EM258 = 24,080. A decrease in absorbance at 258 nm was accompanied by a simultaneous increase in total carbonyls and monoaldehyde content and the appearance of a very weak absorption maximum between 215 and 225 nm. HPLC analysis was done with a Hypersil BDS C8 column with detection at 254 nm and employing a mobile phase consisting of a mixture of buffer and methanol (7:3 v/v) at a pH of 2.25. The buffer consisted of 0.85% H2SO4 in 17.5 mM KH2PO4. The validation results, together with statistical treatment of the data, demonstrated the reliability of both procedures. A drawback of the UV methods was, however, its lack of adequate measurement of sorbic acid stability at higher temperatures. For these assays, the HPLC method was found to be adequate, and it should therefore be used to obtain accurate stability data for sorbic acid in creams.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper describes a comparison between ultraviolet (UV) spectrophotometric and high-performance liquid chromatographic (HPLC) methods of analysis for the determination of sorbic acid in nonionic creams containing lactic acid. Sorbic acid is an antimycotic agent and is used as a preservative in pharmaceuticals, cosmetics, and food products. UV spectrophotometric analysis was done by calculating the concentration of remaining sorbic acid from the absorbance values and the molar extinction coefficient EM258 = 24,080. A decrease in absorbance at 258 nm was accompanied by a simultaneous increase in total carbonyls and monoaldehyde content and the appearance of a very weak absorption maximum between 215 and 225 nm. HPLC analysis was done with a Hypersil BDS C8 column with detection at 254 nm and employing a mobile phase consisting of a mixture of buffer and methanol (7:3 v/v) at a pH of 2.25. The buffer consisted of 0.85% H2SO4 in 17.5 mM KH2PO4. The validation results, together with statistical treatment of the data, demonstrated the reliability of both procedures. A drawback of the UV methods was, however, its lack of adequate measurement of sorbic acid stability at higher temperatures. For these assays, the HPLC method was found to be adequate, and it should therefore be used to obtain accurate stability data for sorbic acid in creams.

Key concepts: Sorbic acid, Chemistry, Chromatography, Absorbance, High-performance liquid chromatography, Preservative, Molar absorptivity, Lactic acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparing HPLC and UV Spectrophotometric Analysis Methods for Determining the Stability of Sorbic Acid in Nonionic Creams Containing Lactic Acid — Research Paper | ScholarLens