2013TELKOMNIKA Indonesian Journal of Electrical EngineeringRequires access

Techniques of Spectrum and Correlation Characteristics for Ultrasonic Ranging System

Tao Gao, Zhenjing Yao, Lifeng Zhang

Open publisher page 0 citations

Abstract

Both the spectrum and correlation characteristics are important in constructing excitation sequences to realize the multichannel ultrasonic sensors working together. For LFM excitation sequence, there should not be too many simultaneously fired ultrasonic sensors, because of the limited available frequency band of the ultrasonic ranging system. The optimized CFM excitation sequences are proposed to trigger multiple-user ultrasonic sensors in this paper. Comparing with the CFM excitation sequences without optimization, the NSGA-II based optimization CFM excitation sequences are more spectrally matched to the ultrasonic ranging system. Moreover, the ultrasonic crosstalk among multichannel sensors of an ultrasonic ranging system can be eliminated. Real experiments using an ultrasonic ranging system consisting of eight-channel SensComp 600 series electrostatic sensors excited with optimized CFM excitation sequences validate the suitability of the proposed method. The idea of optimizing CFM excitation sequences can also be used for the ultrasonic ranging system which has more than eight ultrasonic sensors. DOI : http://dx.doi.org/10.11591/telkomnika.v12i2.4182

About this research paper

What this paper is about

Both the spectrum and correlation characteristics are important in constructing excitation sequences to realize the multichannel ultrasonic sensors working together. For LFM excitation sequence, there should not be too many simultaneously fired ultrasonic sensors, because of the limited available frequency band of the ultrasonic ranging system. The optimized CFM excitation sequences are proposed to trigger multiple-user ultrasonic sensors in this paper. Comparing with the CFM excitation sequences without optimization, the NSGA-II based optimization CFM excitation sequences are more spectrally matched to the ultrasonic ranging system. Moreover, the ultrasonic crosstalk among multichannel sensors of an ultrasonic ranging system can be eliminated. Real experiments using an ultrasonic ranging system consisting of eight-channel SensComp 600 series electrostatic sensors excited with optimized CFM excitation sequences validate the suitability of the proposed method. The idea of optimizing CFM excitation sequences can also be used for the ultrasonic ranging system which has more than eight ultrasonic sensors. DOI : http://dx.doi.org/10.11591/telkomnika.v12i2.4182

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Both the spectrum and correlation characteristics are important in constructing excitation sequences to realize the multichannel ultrasonic sensors working together. For LFM excitation sequence, there should not be too many simultaneously fired ultrasonic sensors, because of the limited available frequency band of the ultrasonic ranging system. The optimized CFM excitation sequences are proposed to trigger multiple-user ultrasonic sensors in this paper. Comparing with the CFM excitation sequences without optimization, the NSGA-II based optimization CFM excitation sequences are more spectrally matched to the ultrasonic ranging system. Moreover, the ultrasonic crosstalk among multichannel sensors of an ultrasonic ranging system can be eliminated. Real experiments using an ultrasonic ranging system consisting of eight-channel SensComp 600 series electrostatic sensors excited with optimized CFM excitation sequences validate the suitability of the proposed method. The idea of optimizing CFM excitation sequences can also be used for the ultrasonic ranging system which has more than eight ultrasonic sensors. DOI : http://dx.doi.org/10.11591/telkomnika.v12i2.4182

Key concepts: Ranging, Ultrasonic sensor, Correlation, Acoustics, Materials science, Physics, Computer science, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Techniques of Spectrum and Correlation Characteristics for Ultrasonic Ranging System — Research Paper | ScholarLens