1997Journal of Agricultural and Food ChemistryRequires access

Time-Resolved Fluoroimmunoassay for the Measurement of Androstenone in Porcine Serum and Fat Samples

Mika Tuomola, Riikka Harpio, Pia Knuuttila, Heikki Mikola, Timo Lövgren

Open publisher page 59 citations

Abstract

A simple competitive time-resolved fluoroimmunoassay was developed for the analysis of the boar taint steroid 5α-androst-16-en-3-one in serum and fat samples. Sensitivities of 30 ng/g and 0.8 ng/mL were obtained for fat and serum measurements, and the assays had mean recoveries of 97% and 103%, respectively. The average coefficients for intra- and interassay variation in fat analysis were 6.0%/8.9%, and in serum measurements 5.4%/8.1%, respectively. Boar fat samples contained androstenone in the range of 130−11570 ng/g ( n = 106), and in the 108 kg boar group, 58% of samples exhibited fat androstenone levels above 500 ng/g. The serum androstenone concentrations in boars ranged from 1.5 to 237.3 ng/mL ( n = 154), but were almost exclusively below the assay range in barrows ( n = 124) and gilts ( n = 83). A significant ( p < 0.0001) correlation was observed between boar serum and fat androstenone concentrations ( r = 0.89, n = 102). A direct serum analysis seems to give a reliable indication of the androstenone level in fat and could be useful in the routine screening for boar taint. Keywords: Androstenone; boar taint; pigs; time-resolved fluoroimmunoassay

About this research paper

What this paper is about

A simple competitive time-resolved fluoroimmunoassay was developed for the analysis of the boar taint steroid 5α-androst-16-en-3-one in serum and fat samples. Sensitivities of 30 ng/g and 0.8 ng/mL were obtained for fat and serum measurements, and the assays had mean recoveries of 97% and 103%, respectively. The average coefficients for intra- and interassay variation in fat analysis were 6.0%/8.9%, and in serum measurements 5.4%/8.1%, respectively. Boar fat samples contained androstenone in the range of 130−11570 ng/g ( n = 106), and in the 108 kg boar group, 58% of samples exhibited fat androstenone levels above 500 ng/g. The serum androstenone concentrations in boars ranged from 1.5 to 237.3 ng/mL ( n = 154), but were almost exclusively below the assay range in barrows ( n = 124) and gilts ( n = 83). A significant ( p < 0.0001) correlation was observed between boar serum and fat androstenone concentrations ( r = 0.89, n = 102). A direct serum analysis seems to give a reliable indication of the androstenone level in fat and could be useful in the routine screening for boar taint. Keywords: Androstenone; boar taint; pigs; time-resolved fluoroimmunoassay

Why it matters

OpenAlex reports 59 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple competitive time-resolved fluoroimmunoassay was developed for the analysis of the boar taint steroid 5α-androst-16-en-3-one in serum and fat samples. Sensitivities of 30 ng/g and 0.8 ng/mL were obtained for fat and serum measurements, and the assays had mean recoveries of 97% and 103%, respectively. The average coefficients for intra- and interassay variation in fat analysis were 6.0%/8.9%, and in serum measurements 5.4%/8.1%, respectively. Boar fat samples contained androstenone in the range of 130−11570 ng/g ( n = 106), and in the 108 kg boar group, 58% of samples exhibited fat androstenone levels above 500 ng/g. The serum androstenone concentrations in boars ranged from 1.5 to 237.3 ng/mL ( n = 154), but were almost exclusively below the assay range in barrows ( n = 124) and gilts ( n = 83). A significant ( p < 0.0001) correlation was observed between boar serum and fat androstenone concentrations ( r = 0.89, n = 102). A direct serum analysis seems to give a reliable indication of the androstenone level in fat and could be useful in the routine screening for boar taint. Keywords: Androstenone; boar taint; pigs; time-resolved fluoroimmunoassay

Key concepts: Androstenone, Boar taint, BOAR, Chemistry, Skatole, Endocrinology, Internal medicine, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Time-Resolved Fluoroimmunoassay for the Measurement of Androstenone in Porcine Serum and Fat Samples — Research Paper | ScholarLens