2005Plastic & Reconstructive SurgeryRequires access

Anatomy of Y-Shaped Configurations in the Subscapular Arterial System and Clinical Application to Harvesting Flow-Through Flaps

Kenji Kawamura, Hiroshi Yajima, Yasunori Kobata, Koji Shigematsu, Yoshinori Takakura

Open publisher page 32 citations

Abstract

BACKGROUND: A flow-through flap is useful in cases where the recipient artery must not be sacrificed. The aim of this study was to investigate Y-shaped configurations in the subscapular arterial system that can safely be used in harvesting a flow-through flap from the scapular region. METHODS: Sixteen dissections of the subscapular arterial system were carried out in eight embalmed cadavers. The origins and external diameters of branches in the subscapular arterial system were recorded. The distances between the origins of each branch were measured. RESULTS: The branches that showed a consistent presence and had a reliable diameter of more than 1.0 mm were the circumflex scapular artery, the bony branch of the circumflex scapular artery, the thoracodorsal artery, the angular branch, and branches to the serratus anterior and latissimus dorsi muscles. It was demonstrated that using the Y-shaped configuration between these branches enables the harvesting of a flow-through flap in various length versions of the Y-shaped vascular pedicles. A significant anatomical variation (i.e., both the thoracodorsal and circumflex scapular artery arose directly from the axillary artery) was found in three of 16 dissections. In this vascular variation, sacrificing the axillary artery must be avoided, so Y-shaped pedicles using the origin of the thoracodorsal or circumflex scapular artery cannot be created. On the basis of these results, flow-through flaps using this arterial system were applied in 10 patients for reconstruction of lower extremities, and satisfactory results were obtained. CONCLUSIONS: The results of our study are available for determining preoperatively and intraoperatively which Y-shaped configuration to use in harvesting a flow-through flap from the scapular region.

About this research paper

What this paper is about

BACKGROUND: A flow-through flap is useful in cases where the recipient artery must not be sacrificed. The aim of this study was to investigate Y-shaped configurations in the subscapular arterial system that can safely be used in harvesting a flow-through flap from the scapular region. METHODS: Sixteen dissections of the subscapular arterial system were carried out in eight embalmed cadavers. The origins and external diameters of branches in the subscapular arterial system were recorded. The distances between the origins of each branch were measured. RESULTS: The branches that showed a consistent presence and had a reliable diameter of more than 1.0 mm were the circumflex scapular artery, the bony branch of the circumflex scapular artery, the thoracodorsal artery, the angular branch, and branches to the serratus anterior and latissimus dorsi muscles. It was demonstrated that using the Y-shaped configuration between these branches enables the harvesting of a flow-through flap in various length versions of the Y-shaped vascular pedicles. A significant anatomical variation (i.e., both the thoracodorsal and circumflex scapular artery arose directly from the axillary artery) was found in three of 16 dissections. In this vascular variation, sacrificing the axillary artery must be avoided, so Y-shaped pedicles using the origin of the thoracodorsal or circumflex scapular artery cannot be created. On the basis of these results, flow-through flaps using this arterial system were applied in 10 patients for reconstruction of lower extremities, and satisfactory results were obtained. CONCLUSIONS: The results of our study are available for determining preoperatively and intraoperatively which Y-shaped configuration to use in harvesting a flow-through flap from the scapular region.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: A flow-through flap is useful in cases where the recipient artery must not be sacrificed. The aim of this study was to investigate Y-shaped configurations in the subscapular arterial system that can safely be used in harvesting a flow-through flap from the scapular region. METHODS: Sixteen dissections of the subscapular arterial system were carried out in eight embalmed cadavers. The origins and external diameters of branches in the subscapular arterial system were recorded. The distances between the origins of each branch were measured. RESULTS: The branches that showed a consistent presence and had a reliable diameter of more than 1.0 mm were the circumflex scapular artery, the bony branch of the circumflex scapular artery, the thoracodorsal artery, the angular branch, and branches to the serratus anterior and latissimus dorsi muscles. It was demonstrated that using the Y-shaped configuration between these branches enables the harvesting of a flow-through flap in various length versions of the Y-shaped vascular pedicles. A significant anatomical variation (i.e., both the thoracodorsal and circumflex scapular artery arose directly from the axillary artery) was found in three of 16 dissections. In this vascular variation, sacrificing the axillary artery must be avoided, so Y-shaped pedicles using the origin of the thoracodorsal or circumflex scapular artery cannot be created. On the basis of these results, flow-through flaps using this arterial system were applied in 10 patients for reconstruction of lower extremities, and satisfactory results were obtained. CONCLUSIONS: The results of our study are available for determining preoperatively and intraoperatively which Y-shaped configuration to use in harvesting a flow-through flap from the scapular region.

Key concepts: Medicine, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Anatomy of Y-Shaped Configurations in the Subscapular Arterial System and Clinical Application to Harvesting Flow-Through Flaps — Research Paper | ScholarLens